Issue 2, 2024

Development of an innovative optical sensor to detect extremely low levels of chromium in real samples using colorimetric methods

Abstract

The investigation focused on a methodology for concentrating and analyzing Cr(VI) in aqueous samples. This objective was accomplished through the creation of a cellulose triacetate (CTA) matrix-based membrane optode. This optode was constructed by physically integrating a specific chromophore, 1,3-benzenediamine,N,N′-bis(2-furanylmethylene) (BDBFM), known for its selectivity towards Cr(VI), alongside the plasticizer dioctylphthalate (DOP). The effectiveness of integrating Aliquat 336, an anion exchanger, was evaluated in the process of immobilizing both BDBFM and the Cr(VI)–BDBFM complex within the optode matrix. The progressive intensification of the violet color observed on the optodes, directly correlating with the amount of loaded Cr(VI), highlights the potential of this method for colorimetric screening of Cr(VI) in aqueous samples. The developed optode was also employed for the determination of the total chromium content by converting Cr(III) to Cr(VI) via oxidation using 0.1 M hydrogen peroxide. The concentration of Cr(III) can be quantified by subtracting the amount of Cr(VI) from the total chromium content. This optode enabled the quantitative detection of Cr(VI), even at levels as low as 2.85 ng mL−1. The suggested sensor displayed a low detection limit, fast response time, cost effectiveness, ease of preparation and also remarkable selectivity regarding some anions and cations. Regeneration of the optode can be easily accomplished by employing 0.05 M HNO3, while demonstrating remarkable reproducibility and reversibility in its response, with a relative standard deviation (RSD) below 1.9. The suggested method was effectively utilized to measure chromium levels in a diverse range of samples, such as food, water, and environmental, and biological samples.

Graphical abstract: Development of an innovative optical sensor to detect extremely low levels of chromium in real samples using colorimetric methods

Article information

Article type
Paper
Submitted
02 sen 2023
Accepted
13 dek 2023
First published
16 dek 2023
This article is Open Access
Creative Commons BY-NC license

Environ. Sci.: Adv., 2024,3, 274-289

Development of an innovative optical sensor to detect extremely low levels of chromium in real samples using colorimetric methods

E. R. Darwish, R. F. Alshehri, A. S. Amin and M. Aish, Environ. Sci.: Adv., 2024, 3, 274 DOI: 10.1039/D3VA00257H

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements