Issue 7, 2012

Single particle inductively coupled plasma mass spectrometry: evaluation of three different pneumatic and piezo-based sample introduction systems for the characterization of silver nanoparticles

Abstract

Engineered nanomaterials are used increasingly around the world. In recent years, environmental concerns have being raised that call for risk assessment, toxicity studies, and nanosafety policies. It is therefore important to provide analytical tools that are able to characterize various types of nanomaterials in a sensitive and fast fashion. In this study, the analytical performance of three sample introduction systems, a PFA micronebulizer with a Peltier-cooled cyclonic spray chamber (PC3), a PFA micronebulizer with a heated cyclonic spray chamber and three-stage Peltier-cooled desolvation system (APEX Q), and a monodisperse droplet generator (Microdrop) with an in-house built spray chamber, was compared for the characterization of silver nanoparticles (Ag NP) with different sizes (20–100 nm) using single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). With continuous polydisperse and pulsed monodisperse droplet sample introduction, single 30 nm NP (PC3) and 20 nm NP (APEX Q, Microdrop), respectively, were successfully detected. Detection efficiencies (20–100 nm Ag NP) were in the range of 5.8 × 10−5 to 8.2 × 10−5 counts per atom, cpa (PC3), 7 × 10−5 to 9.5 × 10−5 cpa (APEX Q), and 8.1 × 10−5 to 1.2 × 10−4 cpa (Microdrop). For a given nanoparticle sample, the variation of the relative standard deviation (RSD) of the size distribution width among the three systems was found to be 1–4% (e.g. 1.3% for 100 nm Ag NP with RSDs of 16.3%, 16.8%, and 17.6% for Microdrop, APEX Q, and PC3, respectively). Size measurements performed by SP-ICP-MS were validated by transmission electron microscopy measurements. Because silver toxicity depends on the silver species in the sample, simultaneous detection of Ag NP and free Ag(I) ions was studied with droplet sample introduction.

Graphical abstract: Single particle inductively coupled plasma mass spectrometry: evaluation of three different pneumatic and piezo-based sample introduction systems for the characterization of silver nanoparticles

Supplementary files

Article information

Article type
Paper
Submitted
03 yan 2012
Accepted
21 fev 2012
First published
22 fev 2012

J. Anal. At. Spectrom., 2012,27, 1074-1083

Single particle inductively coupled plasma mass spectrometry: evaluation of three different pneumatic and piezo-based sample introduction systems for the characterization of silver nanoparticles

B. Franze, I. Strenge and C. Engelhard, J. Anal. At. Spectrom., 2012, 27, 1074 DOI: 10.1039/C2JA00003B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements