Synthesis of MA POSS–PMMA as an intraocular lens material with high light transmittance and good cytocompatibility

Abstract

Poly(methyl methacrylate) (PMMA) has been widely used for intraocular lenses (IOL) but may lead to posterior capsule opacification (PCO) after implantation due to its undesirable hydrophilicity and surface morphology. A novel methacrylisobutyl polyhedral oligomeric silsesquioxane-co-poly methyl methacrylate copolymer (MA POSS–PMMA) was synthesized by a free radical polymerization method to improve its material properties and cytocompatibility. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) and proton nuclear magnetic resonance spectroscopy (1H NMR) measurements demonstrated the successful synthesis of MA POSS–PMMA copolymer. The incorporation of MA POSS greatly changed the crystal structure, surface wettability, optical transmission and cytocompatibility of PMMA. XRD peaks at 2θ ∼ 38.5, 44.7 and 66.1° indicated that a portion of the MA POSS molecules had aggregated and crystallized. Furthermore, larger aggregates are formed at higher MA POSS contents. The optical transmission of the copolymers was up to 99%, which was better than pure PMMA. The hydrophilicity and morphology of the IOL surface were characterized by static water contact angle and atomic force microscopy. Results revealed that MA POSS rendered the surface more hydrophobic and with higher roughness than the pure PMMA. Biocompatibility of copolymers with human lens epithelial cells (HLECs) was further evaluated by morphology and activity measurements in vitro. More HLECs adhesion and better spreading morphology on the surfaces of MA POSS–PMMA copolymers than that on PMMA was shown.

Graphical abstract: Synthesis of MA POSS–PMMA as an intraocular lens material with high light transmittance and good cytocompatibility

Associated articles

Article information

Article type
Paper
Submitted
03 Aug 2014
Accepted
29 Sep 2014
First published
29 Sep 2014

RSC Adv., 2014,4, 52959-52966

Synthesis of MA POSS–PMMA as an intraocular lens material with high light transmittance and good cytocompatibility

B. Wang, Q. Lin, C. Shen, Y. Han, J. Tang and H. Chen, RSC Adv., 2014, 4, 52959 DOI: 10.1039/C4RA08060B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements