Issue 10, 2006

Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters

Abstract

In this work a microflow structure, suitable for μ-FIA (micro flow injection analysis), will be described, evaluated and applied to real samples. Microchannels, the detector flow cell and input/output ports have been micromachined in silicon and sealed with anodically bonded Pyrex glass. The channels are defined by etching approximately 200 µm depth in silicon using a dry reactive ion etching (RIE) process. Optical windows integrated in the chip structure allow simple absorbance/transmission measurements to be made. The optical measurements were made using an LED as emitter (λ = 525 nm) and a photodiode as a detector. A Visual-Basic program has been developed to control an automatic burette, three-way solenoid valves and the data acquisition system. The μ-FIA for nitrite determination using the Griess–Ilosvay reaction has been implemented for the on-line monitoring of wastewater treatment plants (WWTPs). The multicommutation concept has been applied in order to enhance the mixing process inside the microsystem. Tandem streams of reagent and sample were generated and evaluated at different commutation frequencies. Two optimal frequencies, 400/200 ms and 150/450 ms, were found to be the most suitable ones. The first commutation ratio gave rise to wide linear working range (0–250 ppm), in spite of a high detection limit (0.35 ppm) and a low sensitivity (0.0041 ± 0.0004 AU ppm−1). With the second ratio, the working linear range was smaller (0–50 ppm) but the detection limit (0.17 ppm) and the sensitivity (0.0091 ± 0.0003 AU ppm−1) improved remarkably. Finally, real samples with a high nitrite concentration (0–1500 ppm) coming from a study of kinetic inhibition in the nitrification process at a WWTP has been analysed with the proposed μ-FIA system. The obtained results have allowed the corroboration of the model of inhibition by the nitrite ion with great exactitude.

Graphical abstract: Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters

Supplementary files

Article information

Article type
Paper
Submitted
07 Apr 2006
Accepted
27 Jul 2006
First published
18 Aug 2006

Analyst, 2006,131, 1109-1115

Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters

M. D. M. Baeza, N. Ibanez-Garcia, J. Baucells, J. Bartrolí and J. Alonso, Analyst, 2006, 131, 1109 DOI: 10.1039/B605043C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements