Issue 5, 2013

Assessment of recombinant human parathyroid hormone: correlation of LC methods with bioassays

Abstract

Reversed-phase liquid chromatography (RP-LC) and size exclusion liquid chromatography (SE-LC) methods were validated for the assessment of recombinant human parathyroid hormone (rhPTH 1-34). The gradient RP-LC method was carried out on a Zorbax 300 SB C18 column (150 mm × 4.6 mm i.d.), maintained at 40 °C. The mobile phase A consisted of 0.1 M sodium sulphate buffer, pH 2.3, and the mobile phase B was acetonitrile. The SE-LC method was carried out on a BioSep-SEC-S 2000 column (300 mm × 7.8 mm i.d.), maintained at 25 °C. The mobile phase consisted of 0.1 M phosphoric acid buffer, pH 2.5, run isocratically at a flow rate of 0.7 mL min−1. Chromatographic separation was obtained with retention times of 12.2 min, and 13.2 min, and was linear over the concentration range of 1–250 μg mL−1 (r2 = 0.9997) and 2–300 μg mL−1 (r2 = 0.9993), respectively, for RP-LC and SE-LC, with photodiode array (PDA) detection at 214 nm. Specificity was established in degradation studies, which also showed that there was no interference of the excipients. Equally, the accuracy was 100.49% and 100.22%, with bias lower than 1.12% and 0.81% respectively. Moreover, the in vitro cytotoxicity test of related proteins and higher molecular weight forms showed significant differences (p < 0.05). Chromatographic methods were applied for the content/potency assessment of rhPTH and related proteins in biopharmaceutical injectable dosage forms, and the results were correlated with those of in vitro and in vivo bioassays. It is concluded that the employment of the methods in conjunction allows a great improvement in monitoring stability, contributing to evaluate alternatives which improve the quality control and thereby assure the therapeutic efficacy of the biotechnology-derived medicine.

Graphical abstract: Assessment of recombinant human parathyroid hormone: correlation of LC methods with bioassays

Article information

Article type
Paper
Submitted
30 Oct 2012
Accepted
21 Dec 2012
First published
21 Dec 2012

Analyst, 2013,138, 1419-1426

Assessment of recombinant human parathyroid hormone: correlation of LC methods with bioassays

F. P. Stamm, G. Z. Calegari, G. W. de Freitas, R. B. Souto, L. P. Porto, C. D. A. Cardoso and S. L. Dalmora, Analyst, 2013, 138, 1419 DOI: 10.1039/C2AN36583A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements