Issue 18, 2013

Multiplexed DNA detection with a composite molecular beacon based on guanine-quenching

Abstract

We developed a multiplexed DNA detection method with a composite molecular beacon (MB) probe based on guanine-quenching by synchronous fluorescence analysis. It is demonstrated by two types of tumor-suppressor genes namely exon segments of p16 (T1) and p53 (T2) genes. The composite MB probe includes two loops and two stems, and two fluorophores of 6-carboxyfluorescein group (FAM) and tetramethyl-6-carboxyrhodamine (TAMRA) are connected to the two ends of molecular beacon. Every stem portion of MB include four continuous nucleotides with guanine (G) base as quencher, every loop portion is a probe sequence that is complementary to a corresponding target sequence. In the absence of target DNA, the composite MBs are in the stem-closed form, the fluorescence of FAM and TAMRA are quenched by G bases. At this time, the fluorescence signals of FAM and TAMRA are all very low. In the presence of target DNA, the MBs hybridize with the target DNA and form double-strands, FAM and TAMRA are separated from G bases, and the fluorescence of FAM and TAMRA recovers simultaneously. Thus, the simultaneous detection of two targets of DNA can be realized by measuring fluorescence signals of FAM and TAMRA, respectively. Under the optimum conditions, the fluorescence intensities of FAM and TAMRA all exhibit good linear dependence on their target DNA concentration in the range from 5 × 10−11 to 5.5 × 10−9 M. The detection limit of T1 is 4 × 10−11 M (3σ), and that of T2 is 3 × 10−11 M. This composite MB can be applied to detect the real sample, and can be applied to detect two aleatoric sequences of DNA. Compared with previously reported methods of detecting multiplexed target DNA with MBs, the proposed method has some advantages including easy synthesis of composite MB probes, low detection cost and shorter analytical time.

Graphical abstract: Multiplexed DNA detection with a composite molecular beacon based on guanine-quenching

Article information

Article type
Paper
Submitted
27 May 2013
Accepted
20 Jun 2013
First published
20 Jun 2013

Analyst, 2013,138, 5318-5324

Multiplexed DNA detection with a composite molecular beacon based on guanine-quenching

D. Xiang, K. Zhai and L. Wang, Analyst, 2013, 138, 5318 DOI: 10.1039/C3AN01060K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements