Issue 19, 2013

Quantitative determination of flavins – complex analyte/matrix effects in the presence of food colour additives

Abstract

This paper reports a study on analyte/matrix effects of multicomponent FL mixtures of lumichrome (1), 3-methyl-lumiflavin (2), riboflavin (3) in the presence of uric acid (4), redox-stabilizers such as resorufin (5), resazurin (6) and naturally plant originating food color additive maclurin (7), respectively. Sampling complexity, in particular the spatial distribution of the experimental parameters, which can vary widely, is a critical challenge for achieving the selectivity for application to the environmental and foodstuff assays. The random distribution of the analyte in a real sample as well as the systematic and random errors at each of the analytical steps alter the variables of interest. The samples are very complex regarding the nature and matrix effects; significantly alert the recovery, than the choice of an instrumental method for determination, is the most important step. This paper places emphasis on UV-MALDI-Orbitrap-MS among the irreplaceable robust mass spectrometric methods. Despite its conceptually different quantitation procedure from the HPLC-ESI(or APCI)-MS ones, the method provided accurate and precise analytical information over a large concentration range up to 100 fg μL−1, high resolution power and screening ability of individual molecules in complex mixtures, solution, semi-liquid and solid-state analysis, short assay time, fast and step-limited sample pretreatment stages. The reported protocol is constructed on real analytical problems as an effective approach, ensuring maximal data representativeness towards the matrix effects typical for FL assay (pH scale ∈ 2.0–11.8, solvent polarity ε ∈ 7.5–80.1, solvent donor number DN ∈ 14.1–31.5 kcal mol−1, T ∈ 25–300 °C), because of 1–7 stabilized different tautomeric forms, redox states and hydrogen bonding networks. The content included: (a) experimental and theoretical MS analyses and factors stabilizing the ionic fragments in the GP, determining the intensity; (b) full validated (methods and techniques) ESI-, APCI- and MALDI-MS protocols; (c) comparative analysis, employing EAs, LC, HPLC, and UHPLC methods and (d) chemometrics. The promising metrology achieved, beyond that of the reported UPLC-MS/MS, MW-HPLC, and UHPLC ones, evidenced the great capability of the UV-MALDI-Orbitrap-MS method for environmental and foodstuff monitoring versus the widely implemented microbial, chromatographic and spectrometric methods.

Graphical abstract: Quantitative determination of flavins – complex analyte/matrix effects in the presence of food colour additives

Supplementary files

Article information

Article type
Paper
Submitted
14 Jan 2013
Accepted
07 Mar 2013
First published
08 Mar 2013

Anal. Methods, 2013,5, 5134-5145

Quantitative determination of flavins – complex analyte/matrix effects in the presence of food colour additives

B. Ivanova, Anal. Methods, 2013, 5, 5134 DOI: 10.1039/C3AY40077H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.