Issue 13, 2013

Evaluation of poly(vinylpyridine)-supported protoporphyrin resin for the sampling/separation of manganese(ii) using a hyphenated FIA-FAAS system

Abstract

The present study describes the development of a preconcentration method for manganese determination by FAAS using poly(protoporphyrin-co-vinylpyridine) as a sorbent. To synthesize this material, 4-vinylpyridine and protoporphyrin were copolymerized in the presence of ethylene glycol dimethacrylate as a cross-linker and 2,2-azobisisobutyronitrile as an initiator. The factors affecting the flow injection preconcentration system were optimized by employing 25 fractional factorial and Doehlert matrix designs. The proposed on-line preconcentration method was performed by percolating 18.0 mL aliquots of Mn(II) solutions (pH 8.3) at a flow rate of 6.0 mL min−1 through a mini-column, packed with 100 mg of poly(protoporphyrin-co-vinylpyridine); the Mn(II) ions were then on-line eluted with 1.5 mol L−1 HNO3 into the FAAS nebulizer. Under these conditions, it was possible to yield a linear curve in the concentration range of 0.0–120.0 μg L−1, with a correlation coefficient of 0.997. Besides, the following system parameters were obtained: sampling frequency of 15 h−1, preconcentration factor of 53, consumptive index of 0.34 mL, concentration efficiency of 17.6 min−1, detection limit of 0.34 μg L−1, and quantification limit of 1.13 μg L−1. The method precision (repeatability) estimated for ten measurements of 1.0 and 50.0 μg L−1 Mn(II) standard solutions was found to be 5.2 and 4.9%, respectively. Moreover, the protoporphyrin incorporation into the poly(vinylpyridine) network caused a remarkable 323% increase in the method's sensitivity. Finally, the proposed procedure was not affected by potentially interfering ions. Thus, it was successfully applied to the Mn(II) determination in water, food and sediment samples.

Graphical abstract: Evaluation of poly(vinylpyridine)-supported protoporphyrin resin for the sampling/separation of manganese(ii) using a hyphenated FIA-FAAS system

Article information

Article type
Paper
Submitted
07 Feb 2013
Accepted
03 May 2013
First published
07 May 2013

Anal. Methods, 2013,5, 3264-3271

Evaluation of poly(vinylpyridine)-supported protoporphyrin resin for the sampling/separation of manganese(II) using a hyphenated FIA-FAAS system

T. F. de Oliveira, F. M. de Oliveira, M. G. Segatelli and C. R. T. Tarley, Anal. Methods, 2013, 5, 3264 DOI: 10.1039/C3AY40232K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements