Determination of eight artificial sweeteners in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry

Abstract

The development of a method for the simultaneous determination of eight artificial sweeteners, namely aspartame (ASP), alitame (ALI), neotame (NEO), acesulfame (ACS), saccharin (SAC), cyclamate (CYC), sucralose (SCL) and neohesperidin dihydrochalcone (NHDC), under hydrophilic interaction liquid chromatography (HILIC) conditions is presented herein. The ionization of all the compounds was achieved by negative electrospray. Two silica-based columns, a fully porous (XBridge HILIC) and a fused-core one (Kinetex HILIC), were compared. For HILIC optimization, the effect of the following parameters was studied: the mobile phase, column temperature, pH and ionic strength of the ammonium formate buffer. The optimized mobile phase was 5 mM ammonium formate buffer pH 3.5–methanol–acetonitrile (15/10/75 v/v), with a flow rate of 100 μL min−1 at 50 °C. The asymmetry factor of the peaks was lower on the Kinetex HILIC column than that on the XBridge HILIC. The predominant retention mechanism of all the analytes on silica columns seems to be partition to the aqueous layer. The method was validated in tap water and wastewater samples using Kinetex HILIC. Three deuterated internal standards were used, one for each category of sweeteners (dipeptides, sulfamates and sugars). The instrumental limits of detection ranged from 0.24 (SAC) to 4.4 (SCL) μg L−1. The recoveries in influent samples ranged from 39% (CYC) to 97% (NEO), while recoveries were better for the other two matrices. Inter-day precision (%RSD, n = 6) ranged from 4.2% (SAC) to 20% (ALI) in influent samples. The method was applied to influents and effluents from the wastewater treatment plant of Athens for seven consecutive days and high levels of sucralose and sulfamates were found.

Graphical abstract: Determination of eight artificial sweeteners in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
10 Apr 2013
Accepted
03 Jun 2013
First published
03 Jun 2013

Anal. Methods, 2013,5, 3825-3833

Determination of eight artificial sweeteners in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry

M. G. Kokotou and N. S. Thomaidis, Anal. Methods, 2013, 5, 3825 DOI: 10.1039/C3AY40599K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements