Influence of chemical species on the determination of arsenic using inductively coupled plasma mass spectrometry at a low liquid flow rate

Abstract

The effect of common arsenic species on the ICP-MS signal working at a low liquid flow rate was investigated, taking into account the influence of the analytical concentration and of the matrix, comparing various sample introduction systems. Significant decrease (up to 65%) in the relative sensitivity of arsenite compared to arsenate was found, while methylarsonate, dimethylarsinate and arsenobetaine gave the same response (within 6%) as arsenate, throughout the 20–1000 μL min−1 liquid flow rate range. The effect was independent of the analytical concentration in the 1–100 μg L−1 range, and it was ascribed to processes related to both the sample introduction system and the ion generation and transport. Ion defocussing due to dissimilar kinetic energy of the arsenic ions generated from arsenite and arsenate was ruled out. Results obtained by various micronebulizer/spray chamber configurations showed that the temperature of the spray chamber is relevant in determining the relative responses of the arsenic species: heating the spray chamber at 60 °C caused a decrease in relative sensitivity of arsenite and dimethylarsinate compared to arsenate, while the arsenite-to-arsenate signal ratio was improved by cooling at 4 °C. The relative response of arsenite and arsenate was also significantly influenced by the presence of ammonium phosphate, which mitigated the difference between the species using conventional sample introduction devices. The influence of the chemical species on the ICP-MS signal was also investigated for species of other elements, finding significant differences in sensitivity for Hg, Se and Sn compounds when working at a low liquid flow rate. The results proved to have an effect on the accurate quantification of total concentration, as well as for arsenic speciation analysis by μHPLC/ICP-MS.

Graphical abstract: Influence of chemical species on the determination of arsenic using inductively coupled plasma mass spectrometry at a low liquid flow rate

Article information

Article type
Paper
Submitted
03 May 2013
Accepted
10 Jul 2013
First published
10 Jul 2013

J. Anal. At. Spectrom., 2013,28, 1718-1724

Influence of chemical species on the determination of arsenic using inductively coupled plasma mass spectrometry at a low liquid flow rate

M. Grotti, F. Ardini, A. Terol, E. Magi and J. L. Todolí, J. Anal. At. Spectrom., 2013, 28, 1718 DOI: 10.1039/C3JA50159K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements