Abstract

In the light of the exciting recent developments in the detection of Pseudomonas aeruginosa in the breath of cystic fibrosis patients by measuring exhaled HCN, an in vitro study has been conducted to identify and quantify the volatile compounds emitted into the gas phase by other respiratory pathogens. Selected ion flow tube mass spectrometry (SIFT-MS) was used to investigate clinical isolates of Staphylococcus aureus (SA), Streptococcus pneumoniae (SP), and Haemophilus influenzae (HI). Six volatile compounds, mainly alcohols, ketones and aldehydes, were found to be elevated in the headspace of SA cultures and eight were elevated in the SP cultures. It is clear from the mass spectra that a number of other compounds were present at low levels that, as yet, cannot be identified by SIFT-MS alone. Only indole and ethanol were somewhat elevated in the headspace of some of the HI cultures. Principal component analyses (PCA) indicated that the SA cultures clearly separated into two distinct groups in terms of their volatile compound emissions. This may relate to genetic or phenotypic differences. It is postulated that the very efficient production of ethanol and acetaldehyde by SA and SP may provide indicators of airways infection by these bacteria if the levels of these compounds are elevated in exhaled breath above those levels expected due to their normal endogenously produced levels. Plans are in place to check this postulate by breath analysis studies involving patients with pulmonary infections with these organisms.

Graphical abstract: Quantification by SIFT-MS of volatile compounds emitted by in vitro cultures of S. aureus, S. pneumoniae and H. influenzae isolated from patients with respiratory diseases

Article information

Article type
Paper
Submitted
23 Jan 2014
Accepted
01 Mar 2014
First published
13 Mar 2014

Anal. Methods, 2014,6, 2460-2472

Quantification by SIFT-MS of volatile compounds emitted by in vitro cultures of S. aureus, S. pneumoniae and H. influenzae isolated from patients with respiratory diseases

T. W. E. Chippendale, F. J. Gilchrist, P. Španěl, A. Alcock, W. Lenney and D. Smith, Anal. Methods, 2014, 6, 2460 DOI: 10.1039/C4AY00209A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements