Development and application of an analyte/matrix separation procedure for multi-element trace analysis of steel alloys by means of sector-field ICP-mass spectrometry

Abstract

An analytical procedure, based on the use of sector-field ICP-mass spectrometry (ICP-SFMS), was developed for the determination of Be, B, Al, P, S, Ti, Ge, As, Se, Zr, Nb, Rh, Pd, Sn, Sb, Hf, Ta, W, Re, Ir and Pt in a high-alloy steel matrix, consisting mainly of Cr, Fe and Ni, in addition to lower amounts of Si, V, Mn, Co, Cu and Mo. To reduce the impact of spectral and non-spectral interferences, an analyte/matrix separation procedure based on cation-exchange chromatography was developed and applied. In the chromatographic protocol used, most of the first row transition metals are retained on AG 50Wx8 resin, whereby ca. 97.5% of the initial matrix can be separated from the rapidly eluting target elements. The main matrix constituents accompanying the rapidly eluting target elements are Si, Mo and ca. 5% of the total Cr, the latter of which unavoidably elutes prematurely. The finalised procedure was applied to CRMs and real high-alloy steel samples (T91, 316L and 15–15Ti). The experimentally determined concentrations for the CRMs were found to be in good agreement with certified values. Analysis of the real samples revealed the presence of measureable amounts of most of the target elements in at least one of the three steels, with the exception of Be, S, Se, Hf and Ir. For elements not natively found in the CRMs or the real samples under study, recoveries of 100% (within reproducibility uncertainty) were obtained when analysing mock samples. Procedural limits of quantification (10s LoQs) were determined by subjecting blanks to the entire procedure. These were found to range from low ng g−1 levels for Re to sub-mg g−1 levels for S.

Graphical abstract: Development and application of an analyte/matrix separation procedure for multi-element trace analysis of steel alloys by means of sector-field ICP-mass spectrometry

Article information

Article type
Paper
Submitted
18 Feb 2014
Accepted
14 Mar 2014
First published
14 Mar 2014

J. Anal. At. Spectrom., 2014,29, 1073-1081

Author version available

Development and application of an analyte/matrix separation procedure for multi-element trace analysis of steel alloys by means of sector-field ICP-mass spectrometry

T. Tindemans, A. Dobney, D. Wambeke and F. Vanhaecke, J. Anal. At. Spectrom., 2014, 29, 1073 DOI: 10.1039/C4JA00073K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements