Issue 77, 2014

Synthesis and optical properties of emission-tunable PbS/CdS core–shell quantum dots for in vivo fluorescence imaging in the second near-infrared window

Abstract

Near-infrared (NIR) fluorescence imaging at wavelengths from 1000 to 1500 nm (2nd-NIR window) is a promising modality for in vivo fluorescence imaging because of the deeper tissue penetration with lower tissue scattering of the 2nd-NIR light. For such in vivo fluorescence imaging, highly fluorescent probes in the 2nd-NIR wavelength region are needed. Although single-walled carbon nanotubes and Ag2S quantum dots (QDs) have recently appeared as 2nd-NIR fluorescent probes, their fluorescence brightness is relatively low (quantum yields <6%). In this study, we developed a synthetic method for preparing highly fluorescent PbS/CdS core–shell QDs (quantum yields, 17% in water) with narrow band widths (<200 nm) that emit in the 2nd-NIR region. By overcoating of a CdS shell onto a PbS QD core, we could easily control the emission wavelengths of the PbS/CdS QDs at 1000 to 1500 nm. To use the QDs for in vivo imaging, we investigated the optical properties of QDs (penetration depth and blurring of fluorescence images in slices of skin, brain, and heart in mice) in the 2nd-NIR region. We found that the 2nd-NIR fluorescence imaging at ca.1300 nm using the PbS/CdS QDs results in the highest signal to background ratio with a low blurring for in vivo imaging. To confirm the capabilities of the PbS/CdS QDs for in vivo imaging, we conducted fluorescence angiography imaging of a mouse head.

Graphical abstract: Synthesis and optical properties of emission-tunable PbS/CdS core–shell quantum dots for in vivo fluorescence imaging in the second near-infrared window

Supplementary files

Article information

Article type
Paper
Submitted
23 Jun 2014
Accepted
26 Aug 2014
First published
26 Aug 2014

RSC Adv., 2014,4, 41164-41171

Author version available

Synthesis and optical properties of emission-tunable PbS/CdS core–shell quantum dots for in vivo fluorescence imaging in the second near-infrared window

Y. Tsukasaki, M. Morimatsu, G. Nishimura, T. Sakata, H. Yasuda, A. Komatsuzaki, T. M. Watanabe and T. Jin, RSC Adv., 2014, 4, 41164 DOI: 10.1039/C4RA06098A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements