Issue 23, 2015

Mapping explosive residues on galvanized pipe bomb fragments using total vaporization solid phase microextraction (TV-SPME)

Abstract

Solid phase microextraction (SPME) is a popular sampling technique whereby analytes are sorbed to a coated fiber and subsequently desorbed into an analytical instrument. In headspace SPME, analytes partition between the sample, the headspace above the sample, and the SPME fiber coating. In total vaporization SPME (TV-SPME), sample extracts are heated until both the solvent and analytes completely vaporize, whereupon the analytes partition between the vapor phase and the SPME fiber. In this study, TV-SPME using a polyethylene glycol fiber was coupled with fast gas chromatography/mass spectrometry to identify components of double-base smokeless powder (DBSP). Nitroglycerin (NG), diphenylamine (DPA) and ethyl centralite (EC) were separated in under 5 min. For NG, the optimal sample volume (70 μL), extraction temperature (60 °C) and extraction time (20 min) resulted in a method that was over twelve fold more sensitive than traditional liquid injection and with a detection limit below 1 ppb. This method was then used to quantify DBSP residue on post-blast debris from five galvanized steel pipe bombs. The mean concentration of NG on the fragments was 0.25 ppm (w/w). An average of 1.01 mg of NG was recovered from the devices. Finally, the distribution of NG could be “mapped” by tracking the original locations of each fragment within the device. These maps showed that the distribution of NG was far from uniform. In fact, the concentration of the NG on fragments originating from the end caps was several fold higher than in other locations. This finding can help guide the selection of bomb fragments for chemical analyses in real-world scenarios.

Graphical abstract: Mapping explosive residues on galvanized pipe bomb fragments using total vaporization solid phase microextraction (TV-SPME)

Article information

Article type
Paper
Submitted
04 Sep 2015
Accepted
12 Oct 2015
First published
15 Oct 2015

Anal. Methods, 2015,7, 9756-9762

Author version available

Mapping explosive residues on galvanized pipe bomb fragments using total vaporization solid phase microextraction (TV-SPME)

D. Bors and J. Goodpaster, Anal. Methods, 2015, 7, 9756 DOI: 10.1039/C5AY02358K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements