Issue 2, 2015

Neodymium isotope ratio measurements by LC-MC-ICPMS for nuclear applications: investigation of isotopic fractionation and mass bias correction

Abstract

Accurate measurements of neodymium isotope ratios in irradiated nuclear fuel samples are fundamental for the validation of neutronic calculation codes, in particular for burn-up qualification. To prevent possible spectral and non-spectral interferences, neodymium is generally purified from the complex sample matrices prior to measurements by mass spectrometric techniques. This work describes the on-line coupling of ion exchange chromatography with multi-collector inductively coupled plasma mass spectrometry for Nd isotope ratio measurements. In the first part of the paper, the causes of the isotope ratio drifts traditionally observed during transient signal acquisitions are investigated. Both mass-dependent isotopic fractionation on the chromatographic column and distinct time lags between amplifier responses of the Faraday cup configuration were shown to be the main phenomena involved in the observed isotope ratio drifts. In the second part, we present a new approach for mass bias correction called “Intra Injection Sample-Standard Bracketing (IISSB)” based on direct “on-line” injection of the standard via the chromatographic system before and after the analyte. This new method, particularly adapted to analysis of nuclear materials, was validated by on-line measurements on a simulated sample representative of fission products present in an irradiated uranium material. Reproducibilities obtained by IISSB were found to be comparable with those found in off-line measurements and classical sample-standard bracketing technique for mass bias correction on all Nd isotope ratios.

Graphical abstract: Neodymium isotope ratio measurements by LC-MC-ICPMS for nuclear applications: investigation of isotopic fractionation and mass bias correction

Supplementary files

Article information

Article type
Paper
Submitted
24 Oct 2014
Accepted
05 Dec 2014
First published
08 Dec 2014

J. Anal. At. Spectrom., 2015,30, 443-452

Author version available

Neodymium isotope ratio measurements by LC-MC-ICPMS for nuclear applications: investigation of isotopic fractionation and mass bias correction

F. Guéguen, H. Isnard, A. Nonell, L. Vio, T. Vercouter and F. Chartier, J. Anal. At. Spectrom., 2015, 30, 443 DOI: 10.1039/C4JA00361F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements