Issue 106, 2015

Copper phthalocyanine modified SiO2/C electrode as a biomimetic electrocatalyst for 4-aminophenol in the development of an amperometric sensor

Abstract

A selective, simple, and low cost method for 4-aminophenol (4-APh) determination was developed using the mesoporous carbon ceramic SiO2/50 wt% C (SBET = 170 m2 g−1), composite was prepared by the sol–gel method. The material was fabricated to use as matrix to support copper phthalocyanine (CuPc), prepared in situ on their surface, to assure homogeneous dispersion of the electrocatalyst complex in the pores of the matrix. The pressed disk electrodes made of SiO2/C/CuPc was tested as amperometric sensors for 4-APh. Under the optimized conditions, at −75 mV vs. SCE in 0.06 mol dm−3 Britton–Robinson buffer (BRB) solution (pH 7.0) containing 250 μmol dm−3 of H2O2, a linear response range for 4APh from 5 up to 230 μmol dm−3 was obtained with a sensitivity of 123 nA dm−3 μmol−1 cm−2 and the limit of detection LOD was 2 (±0.002) nmol dm−3. The prepared sensors present a stable response during successive determinations. The repeatability, evaluated in terms of relative standard deviation of 3% for n = 10 and μmol dm−3 4-APh. The response time was 1 s and life time 12 months. Finally, the sensor was tested to determine 4-APh in the sample, and gives very good results for its determination. The presence of other phenols like 2-aminophenol, hydroquinone, catechol, cysteine and resorcinol did not show any interference in the detection of 4-APh on this electrode, even in the same concentration with the 4-APh.

Graphical abstract: Copper phthalocyanine modified SiO2/C electrode as a biomimetic electrocatalyst for 4-aminophenol in the development of an amperometric sensor

Supplementary files

Article information

Article type
Paper
Submitted
11 Sep 2015
Accepted
07 Oct 2015
First published
08 Oct 2015

RSC Adv., 2015,5, 87043-87050

Author version available

Copper phthalocyanine modified SiO2/C electrode as a biomimetic electrocatalyst for 4-aminophenol in the development of an amperometric sensor

A. Rahim, N. Muhammad, U. Nishan, U. S. Khan, F. Rehman, L. T. Kubota and Y. Gushikem, RSC Adv., 2015, 5, 87043 DOI: 10.1039/C5RA18617J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements