Issue 26, 2016

PVA-AWP/tyrosinase functionalized screen-printed electrodes for dopamine determination

Abstract

The development of highly sensitive amperometric biosensors for dopamine determination using commercially available SPEs in combination with the PVA-AWP photopolymer as the enzyme immobilization matrix is described in this work. This research focuses on (i) the optimization of the conditions for SPE biofunctionalization by tyrosinase entrapment in PVA-AWP and of the working conditions for dopamine determination by mathematical model application, and (ii) the evaluation of the analytical performances of the PVA-AWP/tyrosinase functionalized SPEs. Dopamine determination under optimum conditions for electrode biofunctionalization (PVA-AWP 3%, 60 min UV light exposure) and under optimum working conditions (pH 6.5, 25 °C) was performed in the dynamic concentration range of 0.9–500 μmol L−1, 0.2–400 μmol L−1, and 0.03–150 μmol L−1, using respectively C SPE, MWCNT-GNP/C SPE, and graphene-GNP/C SPE. The LOD was found to be 300 nmol L−1, 60 nmol L−1, and as low as 10 nmol L−1, correspondingly. The excellent analytical performances of the graphene-GNP C SPE and MWCNT-GNP C SPE were associated with their large active area (19.72 mm2 and 15.3 mm2) and enhanced electrocatalytic properties (ko = 8.1 × 10−3 cm s−1 and 4.4 × 10−3 cm s−1) compared with the bare C SPE (12.47 mm2 and ko = 3.0 × 10−3 cm s−1). The developed biosensors were stable, reproducible, and more sensitive than most of the known biosensors for dopamine determination. They were successfully applied for dopamine determination in injections. Taking into consideration the fact that the selected enzyme immobilization approach using a water-soluble photopolymer opens the possibility of SPE biofunctionalization by photolithography, the developed biosensors are promising for fast, simple, sensitive, selective, and cost effective analysis of dopamine.

Graphical abstract: PVA-AWP/tyrosinase functionalized screen-printed electrodes for dopamine determination

Supplementary files

Article information

Article type
Paper
Submitted
16 May 2016
Accepted
06 Jun 2016
First published
07 Jun 2016

Anal. Methods, 2016,8, 5197-5203

PVA-AWP/tyrosinase functionalized screen-printed electrodes for dopamine determination

M. Stoytcheva, R. Zlatev, F. F. Gonzalez Navarro, Z. Velkova, V. Gochev, G. Montero, A. G. Ayala Bautista and L. Toscano-Palomar, Anal. Methods, 2016, 8, 5197 DOI: 10.1039/C6AY01395C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements