hYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA)

Abstract

Human chitinase 3-like protein 1 (CHI3L1 or hYKL-40), a potential molecular marker for several cancers, was measured in clinical human serum samples and model cell lysates by indirect and competitive enzyme-linked immunosorbent assay (ELISA) and by capacitive immunosensing, so as to evaluate a recently introduced electrochemical method for routine use in cancer-monitoring studies. The clinical samples tested included serum from four healthy individuals, five breast cancer and four glioblastoma patients; cultures of the human monocytic cell line THP-1, known to secrete hYKL-40, and of the human embryonic kidney 293t cell line, which does not express hYKL-40, provided cell lysates and cell culture media for positive and negative bio- and electrochemical control trials. A good agreement was observed between the results of the three tested methods during hYKL-40 quantifications in human serum and cell lysates. Measurements of ‘spiked’ samples from healthy volunteers, cancer patients and hYKL-40-free 293t cell lysates revealed that capacitive immunosensing and the two types of ELISA all recovered the analyte with an efficiency close to 100%. On this basis, capacitive hYKL-40 immunosensor screening is a promising stand-alone or complementary analytical tool for the analysis of hYKL-40 in serum, and would be useful for the validation of standard ELISA data and also, because of the significantly lower hYKL-40 detection limit of the electroanalytical procedure, would permit assay of the marker and cancer observation at earlier stages than is currently possible using ELISA.

Graphical abstract: hYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA)

Supplementary files

Article information

Article type
Paper
Submitted
06 Oct 2016
Accepted
03 Jan 2017
First published
03 Jan 2017

Analyst, 2017,142, 503-510

hYKL-40 cancer biomarker electroanalysis in serum samples and model cell lysates: capacitive immunosensing compared with enzyme label immunosorbent assays (ELISA)

W. Chaocharoen, A. Schulte and W. Suginta, Analyst, 2017, 142, 503 DOI: 10.1039/C6AN02239A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements