Issue 3, 2017

Development of a single-step immunoassay microdevice based on a graphene oxide-containing hydrogel possessing fluorescence quenching and size separation functions

Abstract

An immunoassay, which is an indispensable analytical method both in biological research and in medical fields was successfully integrated into a “single-step” by developing a microdevice composed of a graphene oxide (GO)-containing hydrogel and a poly (dimethylsiloxane) (PDMS) microchannel array with a polyethylene glycol (PEG) coating containing a fluorescently-labelled antibody. Here we used 2-hydroxyethylmethacrylate (HEMA) as a monomer that is easily, and homogeneously, mixed with GO to synthesize the hydrogel. The fluorescence quenching and size separation functions were then optimized by controlling the ratios of HEMA and GO. Free fluorescently-labelled antibody was successfully separated from the immunoreaction mixture by the hydrogel network structure, and the fluorescence was subsequently quenched by GO. In comparison to the previously reported immunoassay system using GO, the present system achieved a very high fluorescence resonance energy transfer (FRET) efficiency (∼90%), due to the use of direct adsorption of the fluorescently-labelled antibody to the GO surface; in contrast, the former reported method relied on indirect adsorption of the fluorescently-labelled antibody via immunocomplex formation at the GO surface. Finally, the single-step immunoassay microdevice was made by combining the developed hydrogel and the PDMS microchannel with a coating containing the fluorescently-labelled antibody, and successfully applied for the single-step analysis of IgM levels in diluted human serum by simple introduction of the sample via capillary action.

Graphical abstract: Development of a single-step immunoassay microdevice based on a graphene oxide-containing hydrogel possessing fluorescence quenching and size separation functions

Supplementary files

Article information

Article type
Paper
Submitted
18 Nov 2016
Accepted
05 Jan 2017
First published
05 Jan 2017

Analyst, 2017,142, 472-477

Development of a single-step immunoassay microdevice based on a graphene oxide-containing hydrogel possessing fluorescence quenching and size separation functions

A. Shirai, K. Nakashima, K. Sueyoshi, T. Endo and H. Hisamoto, Analyst, 2017, 142, 472 DOI: 10.1039/C6AN02485H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.