Re-configurable, multi-mode contained-electrospray ionization for protein folding and unfolding on the millisecond time scale

Abstract

A new reconfigurable contained-electrospray (ES) ion source is described that can be operated in three unique modes (Types I, II and III) and was applied to control the charge state of proteins for subsequent online characterization by mass spectrometry. Using this device, proteins prepared in 100% water were highly charged after exposure to hydrochloric acid vapor. For myoglobin, the shift to a higher charge state occurred faster than the heme cofactor could escape the unfolding protein. This effect reflected in the detection of highly charged holo-myoglobin intermediates (+26), which suggests the modification process occurred on a millisecond time scale (Type I mode). By introducing a cavity in the contained-ES emitter (Type II mode), increased protein denaturation was observed where only apo-myoglobin ions were detected. A similar increase in the charge effect was observed for less pH sensitive proteins such as ubiquitin and cytochrome c. In a third type of experiment, acidified aqueous-based droplets containing unfolded proteins were briefly exposed to aqueous ammonium acetate/triethylammonium acetate solution mixtures to increase the droplet pH and to induce protein folding during electrospray ionization. Charge-state distributions showed protein folding occurred, including the appearance of charged reduced species that were not observed when sprayed in pure water. The three operational modes of contained-electrospray allow online modification of an analyte during charge droplet formation using both vapor and non-volatile liquid reagents, without a direct addition of the modifying reagent to the analyte solution.

Graphical abstract: Re-configurable, multi-mode contained-electrospray ionization for protein folding and unfolding on the millisecond time scale

Supplementary files

Article information

Article type
Paper
Submitted
01 Mar 2017
Accepted
02 May 2017
First published
02 May 2017

Analyst, 2017,142, 2152-2160

Re-configurable, multi-mode contained-electrospray ionization for protein folding and unfolding on the millisecond time scale

C. F. Miller, D. S. Kulyk, J. W. Kim and A. K. Badu-Tawiah, Analyst, 2017, 142, 2152 DOI: 10.1039/C7AN00362E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements