Issue 12, 2017

K-junction structure mediated exponential signal amplification strategy for microRNA detection in electrochemiluminescence biosensor

Abstract

Based on the novel designed K-junction structure, an economic and efficient exponential signal amplification strategy with simple protocol combining hemin/G-quadruplex, a mimetic peroxidase, as a catalyzer was proposed and utilized in an electrochemiluminescence biosensor for sensitive microRNA detection. It was noteworthy that the K-junction structure was formed with guanine-rich reporter DNA and substrate DNA modified by phosphate at the 5′-terminus. Thus, the activity of the reporter DNA could be inhibited and the recognition domain for the target microRNA constructed through the K-junction structure formed. When the target microRNA was sensed, the paired domains of the substrate DNA was completely digested from the 5′-terminus, accompanied by the release of the target microRNA and unpaired DNA fragment of the substrate DNA called the trigger DNA. Afterwards, the released microRNA and trigger DNA were recycled over and over causing the linear and exponential digestion of the K-junction structure, respectively. As a result, numerous uninhibited reporter DNAs were left on the electrode to capture hemin with the yielded hemin/G-quadruplex, which could enhance the ECL emission significantly due to its catalysis for the luminol–H2O2. As expected, this method exhibited excellent specificity and high sensitivity for microRNA detection from 0.033 fM. What's more, the application in human lung cancer cell lines achieved good sensitivity for 10 tumor cells.

Graphical abstract: K-junction structure mediated exponential signal amplification strategy for microRNA detection in electrochemiluminescence biosensor

Article information

Article type
Paper
Submitted
08 Apr 2017
Accepted
02 May 2017
First published
08 May 2017

Analyst, 2017,142, 2185-2190

K-junction structure mediated exponential signal amplification strategy for microRNA detection in electrochemiluminescence biosensor

X. Li, A. Chen, Y. Chai and R. Yuan, Analyst, 2017, 142, 2185 DOI: 10.1039/C7AN00586E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.