Issue 4, 2017

A fluorescent light-up aggregation-induced emission probe for screening gefitinib-sensitive non-small cell lung carcinoma

Abstract

Fluorescent light-up probes with aggregation-induced emission (AIE) characteristics have been focused on recently. In this report, a new fluorescent probe, namely, DEVD-TPE, which consisted of the substrate peptide Asp-Glu-Val-Asp (DEVD) and the AIE reporter group tetraphenylethene (TPE), was developed for detecting caspase-3 in living cells. In a slightly alkaline solution, the DEVD-TPE probe displayed almost no fluorescence owing to the dynamic rotation of the phenyl rings in solution. However, DEVD-TPE exhibited significant fluorescence when it was cleaved by caspase-3, as well as when the reporter group TPE underwent aggregation. The epidermal growth factor receptor (EGFR) inhibitor gefitinib was used for determining the screening efficacy of the probe for different non-small cell lung carcinoma (NSCLC) cell lines, namely, HCC827, A549 and H1650 cells. Cell proliferation and apoptosis assays indicated that the three cell lines had different sensitivities to gefitinib. The results of analysis by living-cell fluorescence imaging and flow cytometry were consistent with those of the cell proliferation and apoptosis assays. This demonstrated that our probe could detect caspase-3 in living cells, which confirmed the apoptosis of NSCLC cells. Furthermore, our probe indicated that gefitinib was more efficient against HCC827 cells than against the other two NSCLC cell lines. This report proves that the fluorescent probe DEVD-TPE is highly sensitive to caspase-3 and has potential prospects in the rapid screening of NSCLC.

Graphical abstract: A fluorescent light-up aggregation-induced emission probe for screening gefitinib-sensitive non-small cell lung carcinoma

Supplementary files

Article information

Article type
Paper
Submitted
11 Jan 2017
Accepted
16 Feb 2017
First published
07 Mar 2017

Biomater. Sci., 2017,5, 792-799

A fluorescent light-up aggregation-induced emission probe for screening gefitinib-sensitive non-small cell lung carcinoma

Y. Hu, L. Shi, Y. Su, C. Zhang, X. Jin and X. Zhu, Biomater. Sci., 2017, 5, 792 DOI: 10.1039/C7BM00035A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements