Issue 4, 2017

Development of on-line UV-induced volatile species generation for selenium speciation [Se(iv) and SeCN] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

Abstract

An on-line UV-induced vapor generation method has been developed that allows simultaneous conversion of selenocyanate [SeCN] and [Se(IV)] to volatile species for their subsequent determination by IC-ICPMS in petroleum refinery wastewater with improved detection limits. The species present in the sample were separated on an anion-exchange column using a step gradient with NaOH as the eluent, and were subsequently converted to their volatile forms by UV irradiation in the presence of a mixture of HCOOH–HNO3 followed by quantitative determination using an ICP-MS. Employing a 200 μL sample injection loop, the species separation was achieved within 7 min and with the best detection limits achieved at 0.01 μg L−1 and 0.06 μg L−1 for SeCN and Se(IV) respectively while the reproducibilities achieved for retention times and peak areas in the chromatograms were better than 1.3% and 5.0% respectively. The method was successfully employed to study the quantitative speciation of selenium in three petroleum refinery wastewaters with accuracy of the results obtained validated by two independent methods. Further validation was carried out by a standard addition method and also by analysing a certified reference material BCR-713, wastewater effluent. Quantitative recoveries (>95%) were observed for both Se(IV) and SeCN in refinery wastewater.

Graphical abstract: Development of on-line UV-induced volatile species generation for selenium speciation [Se(iv) and SeCN−] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

Article information

Article type
Paper
Submitted
28 Nov 2016
Accepted
01 Mar 2017
First published
01 Mar 2017

J. Anal. At. Spectrom., 2017,32, 796-806

Development of on-line UV-induced volatile species generation for selenium speciation [Se(IV) and SeCN] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

K. Chandrasekaran, N. Garg and D. Karunasagar, J. Anal. At. Spectrom., 2017, 32, 796 DOI: 10.1039/C6JA00427J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements