Issue 5, 2017

A three dimensional in vitro glial scar model to investigate the local strain effects from micromotion around neural implants

Abstract

Glial scar formation remains a significant barrier to the long term success of neural probes. Micromotion coupled with mechanical mismatch between the probe and tissue is believed to be a key driver of the inflammatory response. In vitro glial scar models present an intermediate step prior to conventional in vivo histology experiments as they enable cell–device interactions to be tested on a shorter timescale, with the ability to conduct broader biochemical assays. No established in vitro models have incorporated methods to assess device performance with respect to mechanical factors. In this study, we describe an in vitro glial scar model that combines high-precision linear actuators to simulate axial micromotion around neural implants with a 3D primary neural cell culture in a collagen gel. Strain field measurements were conducted to visualize the local displacement within the gel in response to micromotion. Primary brain cell cultures were found to be mechanically responsive to micromotion after one week in culture. Astrocytes, as determined by immunohistochemical staining, were found to have significantly increased in cell areas and perimeters in response to micromotion compared to static control wells. These results demonstrate the importance of micromotion when considering the chronic response to neural implants. Going forward, this model provides advantages over existing in vitro models as it will enable critical mechanical design factors of neural implants to be evaluated prior to in vivo testing.

Graphical abstract: A three dimensional in vitro glial scar model to investigate the local strain effects from micromotion around neural implants

Supplementary files

Article information

Article type
Paper
Submitted
14 Nov 2016
Accepted
13 Jan 2017
First published
13 Jan 2017

Lab Chip, 2017,17, 795-804

A three dimensional in vitro glial scar model to investigate the local strain effects from micromotion around neural implants

K. C. Spencer, J. C. Sy, R. Falcón-Banchs and M. J. Cima, Lab Chip, 2017, 17, 795 DOI: 10.1039/C6LC01411A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements