Issue 33, 2017

Graphene-based multiplexed disposable electrochemical biosensor for rapid on-farm monitoring of NEFA and βHBA dairy biomarkers

Abstract

Elevated circulating concentrations of non-esterified fatty acids (NEFA) and beta hydroxy butyrate (βHBA) in biological fluids are recognized as critical biomarkers for early diagnosis of negative energy balance (NEB) in dairy cows. Herein, we report the development of a cost-effective, bio-friendly and electrochemically active dual screen printed electrode (SPE) sensor platform composed of electro-reduced graphene oxide nanosheets (E-rGO) modified with specific antibodies against NEFA and βHBA. The chemically synthesized graphene oxide (GO) was reduced directly on the screen printed electrode (SPE) surface via a green electrochemical approach without using toxic chemicals. The E-rGO was characterized using various analytical techniques, like XPS, SEM, TEM, AFM, UV-Vis, Raman spectroscopy, FTIR, and XRD, to get insight into its properties. Electrochemical analysis demonstrates that the E-rGO-modified SPE electrodes exhibit enhanced and durable redox properties as compared to the pristine graphite and GO electrodes. Target specificity is accomplished through immobilization of specific antibodies against NEFA and βHBA over the nanostructure-modified surface of the SPE, which only interacts with its counterpart NEFA and βHBA only. The antibodies retain their characteristic immuno-complex formation property upon immobilization and exhibit changes to amperometric signals upon interaction with various concentrations of NEFA and βHBA in standard, spiked blood and real clinical samples. The DPV signals resulted from the developed immunosensor platform exhibited a good correlation (R2 ∼ 0.99 for both NEFA and βHBA) for a wide range of target concentrations from 0.1 mM to 10 mM. The proposed immunosensor design not only provides a rapid analytical response time (≥1 min), but also simplicity in fabrication and instrumentation, which may provide a promising approach for on-farm diagnostics of ketosis and metabolic disorders associated with NEB.

Graphical abstract: Graphene-based multiplexed disposable electrochemical biosensor for rapid on-farm monitoring of NEFA and βHBA dairy biomarkers

Supplementary files

Article information

Article type
Paper
Submitted
19 May 2017
Accepted
31 Jul 2017
First published
01 Aug 2017

J. Mater. Chem. B, 2017,5, 6930-6940

Graphene-based multiplexed disposable electrochemical biosensor for rapid on-farm monitoring of NEFA and βHBA dairy biomarkers

S. K. Tuteja, T. Duffield and S. Neethirajan, J. Mater. Chem. B, 2017, 5, 6930 DOI: 10.1039/C7TB01382E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements