Issue 20, 2018

Multi-lumen capillary based trypsin micro-reactor for the rapid digestion of proteins

Abstract

In this work we evaluated a novel microreactor prepared using a surface modified, high surface-to-volume ratio multi-lumen fused silica capillary (MLC). The MLC investigated contained 126 parallel channels, each of 4 μm internal diameter. The MLC, along with conventional fused silica capillaries of 25 μm and 50 μm internal diameter, were treated by (3-aminopropyl)triethoxysilane (APTES) and then modified with gold nanoparticles, of ∼20 nm in diameter, to ultimately provide immobilisation sites for the proteolytic enzyme, trypsin. The modified capillaries and MLCs were characterised and profiled using non-invasive scanning capacitively coupled contactless conductivity detection (sC4D). The sC4D profiles confirmed a significantly higher amount of enzyme was immobilised to the MLC when compared to the fused silica capillaries, attributable to the increased surface to volume ratio. The MLC was used for dynamic protein digestion, where peptide fragments were collected and subjected to off-line chromatographic evaluation. The digestion was achieved with the MLC reactor, using a residence time of just 1.26 min, following which the HPLC peak associated with the intact protein decreased by >70%. The MLC reactors behaved similarly to the classical in vitro or in-solution approach, but provided a reduction in digestion time, and fewer peaks associated with trypsin auto-digestion, which is common using in-solution digestion. The digestion of cytochrome C using both the MLC-IMER and the in-solution approach, resulted in a sequence coverage of ∼80%. The preparation of the MLC microreactor was reproducible with <2.5% RSD between reactors (n = 3) as determined by sC4D.

Graphical abstract: Multi-lumen capillary based trypsin micro-reactor for the rapid digestion of proteins

Supplementary files

Article information

Article type
Paper
Submitted
17 Jul 2018
Accepted
08 Sep 2018
First published
10 Sep 2018

Analyst, 2018,143, 4944-4953

Multi-lumen capillary based trypsin micro-reactor for the rapid digestion of proteins

S. A. Currivan, W. Q. Chen, R. Wilson, E. Sanz Rodriguez, N. Upadhyay, D. Connolly, P. N. Nesterenko and B. Paull, Analyst, 2018, 143, 4944 DOI: 10.1039/C8AN01330F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements