Issue 10, 2018

High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket

Abstract

Wide application of stable Ca isotopes requires reliable production of high-precision data and in recent years multiple collector inductively coupled plasma mass spectrometers (MC-ICP-MS) have been used as an alternative to traditional thermal ionization mass spectrometers. The main challenges in using MC-ICP-MS to measure stable Ca isotopes are scattered ions and peak tailing of high level 40Ar+ and 40Ca+ ion beams, along with variable interferences. In this study we optimize Ca isotopic measurements on a large geometry high resolution MC-ICP-MS (Nu Plasma 1700) operating in conventional hot Ar-plasma mode. 40Ar+ and 40Ca+ were trapped by a specially designed dummy bucket, to prevent scattering of ions that might affect the Ca isotopic measurement. Strontium and matrix elements in samples were eliminated to blank levels by chemical separation. Instrumental mass bias of Ca isotopes was corrected by a sample-standard bracketing method using a purified sea water Ca isotope standard. Potential effects of Ar-related interferences, Ca-hydride, acid molarity, concentration mismatch and matrix elements were evaluated. The results from both measurements and modeling suggest that 40Ar+ peak tailing and Ca-hydride cause negligible Ca isotopic offset under normal MC-ICP-MS operating conditions. The precision and accuracy were validated using the measurement of twelve well-characterized international reference materials and a pure Ca standard solution. The long-term external precisions are better than ±0.07‰ (2SD) for δ44/42Ca and ±0.10‰ (2SD) for δ43/42Ca. Calcium isotopic compositions of all reference materials measured in this study agree with previously published data within uncertainties.

Graphical abstract: High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket

Supplementary files

Article information

Article type
Paper
Submitted
12 Jul 2018
Accepted
15 Aug 2018
First published
21 Aug 2018

J. Anal. At. Spectrom., 2018,33, 1707-1719

High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket

M. Li, Y. Lei, L. Feng, Z. Wang, N. S. Belshaw, Z. Hu, Y. Liu, L. Zhou, H. Chen and X. Chai, J. Anal. At. Spectrom., 2018, 33, 1707 DOI: 10.1039/C8JA00234G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements