Issue 19, 2018, Issue in Progress

Nafion®-coated mesoporous Pd film toward remarkably enhanced detection of lactic acid

Abstract

Mesoporous metal films can detect biomarkers with high sensitivity. Further coating the mesoporous metal with polymers enhances sensing selectivity by favoring specific biomarkers against other interferents. In the present study, we report the fabrication of a Nafion®-coated mesoporous Pd film to filtrate interferents present in sweat during non-invasive biosensing. By using a Nafion®-coated mesoporous Pd film, lactic acid, a metabolite present in sweat, can be successfully detected with high sensitivity.

Graphical abstract: Nafion®-coated mesoporous Pd film toward remarkably enhanced detection of lactic acid

Supplementary files

Article information

Article type
Paper
Submitted
04 Dec 2017
Accepted
26 Feb 2018
First published
14 Mar 2018
This article is Open Access
Creative Commons BY license

RSC Adv., 2018,8, 10446-10449

Nafion®-coated mesoporous Pd film toward remarkably enhanced detection of lactic acid

D. Baba, A. S. Nugraha, M. Iqbal, J. Bo, C. Li, A. A. Alshehri, J. You, V. Malgras, Y. Yamachi and T. Asahi, RSC Adv., 2018, 8, 10446 DOI: 10.1039/C7RA13026K

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements