Improving the analytical performance of electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry using a mixed-gas plasma

Abstract

A robust Ar–N2 mixed-gas plasma is proposed to improve the analytical performance of electrothermal vapourization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES). With 0.4 L min−1 of N2 in the plasma gas flow and 20 mL min−1 of N2 sheathing gas in the central channel of the ICP, sensitivity based on peak area increased by up to 32 fold (Ba) and detection limits improved by up to 300 fold (Ba). Detection limits, based on 3 mg aliquots, ranged from 0.007 (Mo, Sb) to 100 (Mg) mg kg−1 with the mixed-gas plasma versus 0.01 (Tl) – 3000 (Al) mg kg−1 with an Ar plasma. Such improvement was in general more important for ionic than atomic emission lines under the optimized ETV conditions: 8 mL min−1 CHF3 (as chemical modifier), 0.15 L min−1 Ar carrier gas, 0.50 L min−1 Ar by-pass gas, 400 °C pyrolysis for 20 s; cool down to 20 °C for 15 s and 2200 °C vaporization for 30 s. The relative standard deviation ranged from 0.4 to 19% for 3 mg soil replicates (n = 10). Point-by-point internal standardization with Ar I 763.511 nm was systematically applied to compensate for sample loading effects in the ICP. The lower suppression of the Ar I 763.511 nm signal caused by the ETV effluent in the mixed-gas plasma compared to an Ar plasma confirmed the higher robustness of the mixed-gas plasma. Additional studies revealed that only Ar atomic emission lines (at 763.511, 415.859 and 420.067 nm) with similar energy (11.5 eV) to that of Ar metastable species (Arm) showed reproducible suppression, suggesting a major role of Arm on plasma-related matrix effects. Accurate results were obtained for 41–65% of the elements with certified concentrations in three soil certified reference materials by direct soil analysis using another soil certified reference material for external calibration.

Graphical abstract: Improving the analytical performance of electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry using a mixed-gas plasma

Supplementary files

Article information

Article type
Paper
Submitted
14 Jan 2019
Accepted
07 Feb 2019
First published
07 Feb 2019

J. Anal. At. Spectrom., 2019,34, 891-898

Improving the analytical performance of electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry using a mixed-gas plasma

G. L. Scheffler, D. Pozebon and D. Beauchemin, J. Anal. At. Spectrom., 2019, 34, 891 DOI: 10.1039/C9JA00010K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements