Issue 9, 2019

Study on carbon-induced signal enhancement in inductively coupled plasma mass spectrometry: an approach from the spatial distribution of analyte signal intensities

Abstract

To obtain further insight into the mechanism of carbon-induced signal enhancement, accurate quantification of carbon-induced signal enhancement in inductively coupled plasma mass spectrometry (ICP-MS) has been examined. Spatial intensity distributions and axial intensity profiles of the analyte ion (M+) in ICP were obtained by measuring elemental solutions with and without carbon (i.e., 5% (v/v) 2-propanol, IPA). Addition of 5% (v/v) IPA significantly spread and shifted the M+ intensity zone, particularly in the axial direction, toward the sampling cone. The result indicated that the carbon-induced zone-shift in the axial direction should be considered for accurate quantification. As an index for quantifying carbon-induced signal enhancement, an enhancement factor (EFsum), was defined based on the axial intensity profiles by dividing the sum of analyte signal intensities for axial sampling positions from 4 to 15 mm, obtained with 5% (v/v) IPA, by the sum of those obtained without 5% (v/v) IPA. The EFsum values were estimated for 26 elements with a wide range of first ionization energies (IEs) and analyte oxide bond dissociation energies (BDEs). There was no clear relationship between EFsum values and IEs or BDEs of elements, even though the existing hypotheses about the mechanism of carbon-induced signal enhancement have suggested that IE or BDE was a major factor that determines carbon-induced signal enhancement. Large EFsum values were estimated for P, As, Se, and I. Chemical forms of these elements in elemental solutions are oxoacids in common. The results might imply that a mechanism that depends on the chemical forms of elements is also involved in carbon-induced signal enhancement.

Graphical abstract: Study on carbon-induced signal enhancement in inductively coupled plasma mass spectrometry: an approach from the spatial distribution of analyte signal intensities

Supplementary files

Article information

Article type
Paper
Submitted
26 Apr 2019
Accepted
27 Jun 2019
First published
19 Jul 2019

J. Anal. At. Spectrom., 2019,34, 1865-1874

Study on carbon-induced signal enhancement in inductively coupled plasma mass spectrometry: an approach from the spatial distribution of analyte signal intensities

T. Ariga, Y. Zhu and K. Inagaki, J. Anal. At. Spectrom., 2019, 34, 1865 DOI: 10.1039/C9JA00152B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.