Issue 9, 2019

Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry

Abstract

This study presents the first high precision method to analyze stable Zr isotope ratios in zircons using laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). Interference problems for in situ Zr isotope analysis were investigated in detail. The polyatomic interferences of 89Y1H+ and doubly charged ion interference of 180Hf++ did not influence the Zr isotope analysis. The addition of 8 ml min−1 nitrogen to the central gas flow in LA-MC-ICP-MS was found to increase the sensitivity of Zr by a factor of 1.95. The analysis mode of small laser spot sizes (16–32 μm) and low laser frequency (1 Hz) combined with a signal-smoothing device was used. Compared to that without the signal-smoothing device, the obtained analytical precision was improved by about 60.6 times by using the signal-smoothing device at the low laser frequency (1 Hz). The accuracy of the in situ method is validated by comparing the data to those of a well-established double spike solution method. Data for six international zircon standards and six additional natural zircons are given. The data are reported as standard delta notation as the permil deviation of the 94Zr/90Zr (δ94/90ZrGJ-1) and 96Zr/90Zr (δ96/90ZrGJ-1) ratios relative to the GJ-1 zircon standard. Typical intermediate precisions for δ94/90ZrGJ-1 and δ96/90ZrGJ-1 were 0.11 and 0.18‰ (2SD, standard deviation). The δ94/90ZrGJ-1 values for the four zircon reference materials (91500, Plešovice, Penglai and Mud Tank) determined by LA-MC-ICP-MS were in good agreement with those of double spiked solution measurements, confirming the accuracy of the in situ method. The zircon reference material FC1 showed the largest stable isotope fractionation of 4.93‰ for δ94/90ZrGJ-1. One natural zircon (08KQ02-1) with a complex history showed a significant δ94/90ZrGJ-1 isotope variation in the single grain. These results suggest that Zr isotopes are a potentially powerful geochemical tracer and that high spatial-resolution, in situ determination like by the LA-MC-ICP-MS method in this study is rather important to identify Zr isotope variation in single zircon grains.

Graphical abstract: Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
03 Jun 2019
Accepted
01 Jul 2019
First published
01 Jul 2019

J. Anal. At. Spectrom., 2019,34, 1800-1809

Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry

W. Zhang, Z. Wang, F. Moynier, E. Inglis, S. Tian, M. Li, Y. Liu and Z. Hu, J. Anal. At. Spectrom., 2019, 34, 1800 DOI: 10.1039/C9JA00192A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements