Issue 35, 2019

Lanthanide grafted phenanthroline-polymer for physiological temperature range sensing

Abstract

Accurate measurement of the temperature is crucial as it determines the dynamics of almost any system. Conventional contact thermometers are not well suited for small scale measurements. Temperature dependent luminescent materials, i.e. materials that emit light of different color at different temperature, are therefore of particular interest in the development of noncontact thermometers. Luminescent materials consisting of lanthanide ions feature high thermal sensitivity, high photostability and high quantum yields. These ions possess very interesting light emitting properties. By anchoring them onto different backbone materials, their light absorption is increased. The search for a backbone that allows the sensor to be active in a defined temperature range, with a high detection sensitivity is ongoing. This work reports the first insoluble phenanthroline-polymer (phen-polymer) backbone on which europium (Eu3+) and terbium (Tb3+) trifluoroacetylacetone (tfac) complexes are easily grafted in a 1 : 1 metal ratio in order to create a noncontact temperature sensor. Two clear, discriminable emission peaks were observed during the photoluminescence study at room temperature, demonstrating that this material can be used as a ratiometric thermometer. The characteristic emission peak correlated to Eu3+ transition is slightly stronger than the emission peak of Tb3+ transition, resulting in a yellow emission color. The maximum value of the relative temperature sensitivity was calculated to be 2.3404% K−1 (340 K), which indicated good thermometric behavior. The emission color of the designed phen-polymer@Eu,Tb_tfac changed from light green (260 K) to orange-red (460 K). The thermometer can therefore be used as a ratiometric noncontact temperature sensor in the broad physiological temperature range.

Graphical abstract: Lanthanide grafted phenanthroline-polymer for physiological temperature range sensing

Supplementary files

Article information

Article type
Paper
Submitted
02 May 2019
Accepted
16 Aug 2019
First published
16 Aug 2019

J. Mater. Chem. C, 2019,7, 10972-10980

Lanthanide grafted phenanthroline-polymer for physiological temperature range sensing

F. Vanden Bussche, A. M. Kaczmarek, J. Schmidt, C. V. Stevens and P. Van Der Voort, J. Mater. Chem. C, 2019, 7, 10972 DOI: 10.1039/C9TC02328C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements