Issue 8, 2020

Three-dimensional macroporous gold electrodes superior to conventional gold disk electrodes in the construction of an electrochemical immunobiosensor for Staphylococcus aureus detection

Abstract

Herein, a three-dimensional macroporous gold (3DMG) electrode is demonstrated to be a better choice than a conventional gold disk electrode in the construction of an electrochemical immunobiosensor for Staphylococcus aureus (S. aureus) detection. The 3DMG electrode was prepared on a gold disk electrode by one-step electrodeposition using hydrogen bubbles as dynamic templates. The 3DMG electrode has a high electrochemically active surface area with pore sizes ranging from 20 to 50 μm, and these unique features are conducive to the immobilization of primary antibodies and the capture of S. aureus. Secondary antibodies (Ab2) and alkaline phosphatase (ALP) were immobilized on mesoporous silica nanospheres (MSNs), and the resulting ALP-MSNs-Ab2 composites were utilized as signal tags to construct a sandwich-type electrochemical immunobiosensor. S. aureus was measured based on alkaline phosphatase-catalyzed silver deposition and differential pulse voltammetric detection. The linear range is from 5 to 109 CFU mL−1, and the detection limit is 2 CFU mL−1 for S. aureus detection. Due to the signal amplification of the 3DMG electrode, the sensitivity of the immunobiosensor constructed on the 3DMG electrode is 9 times that of an immunobiosensor constructed on a gold disc electrode. The proposed biosensor was successfully applied for detecting S. aureus in milk samples.

Graphical abstract: Three-dimensional macroporous gold electrodes superior to conventional gold disk electrodes in the construction of an electrochemical immunobiosensor for Staphylococcus aureus detection

Supplementary files

Article information

Article type
Paper
Submitted
27 Nov 2019
Accepted
13 Feb 2020
First published
14 Feb 2020

Analyst, 2020,145, 2988-2994

Three-dimensional macroporous gold electrodes superior to conventional gold disk electrodes in the construction of an electrochemical immunobiosensor for Staphylococcus aureus detection

H. Wang, X. Zhao, H. Yang, L. Cao, W. Deng, Y. Tan and Q. Xie, Analyst, 2020, 145, 2988 DOI: 10.1039/C9AN02392E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements