Issue 17, 2020

Picoliter enzyme reactor on a nanofluidic device exceeding the bulk reaction rate

Abstract

Single-cell analyses have recently become important to understand cell heterogeneity, the mechanism of cell function, and diseases. In contrast to single-cell analyses that target nucleic acids, single-cell protein analyses still pose challenges. We have proposed a general concept of integration and extended this concept to the 10–1000 nm scale with femtoliter–picoliter volumes which are smaller than the volume of a single cell exploring ultimate analytical performances (e.g. single-cell target proteomics). However, single-cell shotgun proteomics, which is used to analyze even unknown proteins, is still challenging because there is no digestion column with picoliter volume. The issues were long reaction time (overnight) and much larger reaction volume (microliter) in the conventional bulk method. In this study, an ultra-fast picoliter enzyme reactor using a nanochannel was developed. A device with a channel depth of 300 nm and a volume of 32.4 pL was fabricated. To prevent the self-digestion of trypsin (enzyme), the picoliter enzyme reactor was prepared by immobilizing trypsinogen which was activated to trypsin by enterokinase. The enzyme density obtained by the trypsinogen immobilization process was 2.5 times higher than that obtained by the conventional trypsin immobilization process. Furthermore, the apparent enzyme concentration was 36 times higher due to an extremely high surface-to-volume ratio of the nanochannel, compared to the limit concentration in the bulk. Finally, the enzyme reaction in the picoliter enzyme reactor was accelerated 25 times compared to that in the bulk. Using the picoliter enzyme reactor, protein solution with picoliter volume will be digested without self-digestion and artificial modification, which will greatly contribute to single-cell shotgun proteomics.

Graphical abstract: Picoliter enzyme reactor on a nanofluidic device exceeding the bulk reaction rate

Supplementary files

Article information

Article type
Paper
Submitted
18 May 2020
Accepted
29 Jun 2020
First published
01 Jul 2020

Analyst, 2020,145, 5801-5807

Author version available

Picoliter enzyme reactor on a nanofluidic device exceeding the bulk reaction rate

K. Yamamoto, K. Morikawa, H. Imanaka, K. Imamura and T. Kitamori, Analyst, 2020, 145, 5801 DOI: 10.1039/D0AN00998A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements