Quantitative determination of trace level (ng g−1) contents of rhodium and palladium in copper-rich minerals using LA-ICP-MS

Abstract

This study reports on the efficacy of measuring low ng g−1 contents of Rh and Pd in Cu-rich minerals by laser ablation single quadrupole (Agilent 7700x) and tandem MS (Agilent 8900x) ICP-MS, using helium (He) collision gas and a mixture of ammonia (NH3)/He (10%/90%) reaction gas, respectively, to attenuate CuAr interferences on 103Rh and 105Pd. Results are compared with values obtained from digested separates of the same minerals (three synthetic Cu-rich Fe sulphides, seven samples of chalcopyrite (CuFeS2) and two of bornite (Cu5FeS4) containing 24.17% to 63.31% Cu, less than 10 ng g−1 Rh and less than 250 ng g−1 Pd) analyzed using an Agilent 8800x ICP-MS/MS in NH3/He reaction mode. Using the LA-ICP-MS/MS at an optimized NH3/He flow rate (0.3 mL min−1), the CuAr contributions to 103Rh and 105Pd were less than 2.3 ng g−1, which was a reduction of more than two orders of magnitude compared to those obtained using the single quadrupole LA-ICP-MS at an optimized He collision gas flow (5 mL min−1). The method limits of detection (MLOD) for 103Rh (1.7 ng g−1) and 105Pd (7.0 ng g−1) obtained using LA-ICP-MS/MS at the optimized NH3/He flow rate with a 110 μm ablation spot size were approximately an order of magnitude lower than those (16 ng g−1 for Rh and 48 ng g−1 for Pd) obtained using single quadrupole LA-ICP-MS at the optimized He collision gas flow rate. The accuracy (difference from values for digested separates) and precision (1RSD) of ng g−1-level LA-ICP-MS/MS measurements of Rh and Pd (105Pd) in Cu-rich minerals were in the range of 0.5% to 19% and 19% to 31%, respectively. Moreover, this study shows that neither a linear CuAr interference correction strategy nor the interference correction procedure of P. J. Sylvester, Mineral. Assoc. Can., Short Course Ser., 2001, vol. 29, p. 203 works effectively for accurate and precise LA-ICP-MS measurement of low ng g−1 contents of Rh and Pd in Cu-rich minerals. The most accurate and precise measurement of Rh at less than 10 ng g−1 and Pd at ca. 100 ng g−1 in Cu-rich minerals is achieved using the Agilent 8900x LA-ICP-MS/MS in MS/MS acquisition mode at an optimized NH3/He reaction gas flow rate without a CuAr interference correction. These results demonstrate the potential for LA-ICP-MS/MS to be widely used for the quantitative determination of trace level contents of the light PGE in transition metal sulphide minerals.

Graphical abstract: Quantitative determination of trace level (ng g−1) contents of rhodium and palladium in copper-rich minerals using LA-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
13 Aug 2019
Accepted
20 Jan 2020
First published
20 Jan 2020

J. Anal. At. Spectrom., 2020,35, 534-547

Quantitative determination of trace level (ng g−1) contents of rhodium and palladium in copper-rich minerals using LA-ICP-MS

Z. Yang, S. E. Jackson, L. J. Cabri, P. Wee, H. P. Longerich and M. Pawlak, J. Anal. At. Spectrom., 2020, 35, 534 DOI: 10.1039/C9JA00285E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements