Issue 7, 2020

An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket

Abstract

Previous studies have shown that significant K isotope fractionation is found in continental weathering, oceanic crust subduction, and plant growth, suggesting that K isotopes could be a potentially important tracer. However, the complicated separation method and analytical conditions limit the precise analysis of potassium isotopes via MC-ICP-MS under “cold” plasma conditions. Here, an improved separation method (single column) permits the complete purification of K from the matrix elements. This method is efficient and convenient and achieves a high yield (99.5 ± 0.6%) and low blank (<10 ng K) under complex matrix extraction conditions. The high-resolution mode with a desolvating nebulizer system was used to increase the signal intensity of 41K+ and 39K+ and reduce 38ArH+, 40ArH+, and some oxide/nitride interference. To eliminate scattered ions or secondary electrons, we used a new dummy bucket to collect high intensity 40Ar+ beams. Besides, potassium isotopes for the standard SRM 3141a and new geological, environmental and biological reference materials such as DNC-1a, JMS-2, and GSB-14 were determined on a Nu Plasma 3 MC-ICP-MS instrument. Overall, the reproducibility of K isotope analysis was better than ±0.06‰ (2SD) that reported in most laboratories around the world. The measured δ41K values of the rock samples are homogeneous, consistent with the previous published data. However, the K isotope composition in soils, sediments, and plants is inhomogeneous and varies greatly from −0.85‰ to −0.25‰. These results show that potassium isotopes have great application potential in the geological, environmental, and biological fields.

Graphical abstract: An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket

Supplementary files

Article information

Article type
Paper
Submitted
30 Mar 2020
Accepted
09 Jun 2020
First published
10 Jun 2020

J. Anal. At. Spectrom., 2020,35, 1330-1339

An optimal separation method for high-precision K isotope analysis by using MC-ICP-MS with a dummy bucket

X. Li, G. Han, Q. Zhang and Z. Miao, J. Anal. At. Spectrom., 2020, 35, 1330 DOI: 10.1039/D0JA00127A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements