Direct analysis of wheat flour by inductively coupled plasma mass spectrometry with flow injection, slurry nebulization, and a mixed-gas plasma

Abstract

Inductively coupled plasma mass spectrometry (ICPMS) is well suited for vegetation analysis. Slurry nebulization offers an attractive alternative to traditional digestions that increase the risk of sample contamination and analyte loss. By simply grinding the sample very finely and suspending it in solution the material can be nebulized directly. While ICPMS has been used for slurry nebulization, it is susceptible to matrix effects. Mixed-gas plasmas have been shown to reduce or eliminate these matrix effects by increasing energy transfer between the bulk plasma and the central channel. This contribution uses flow injection and slurry nebulization for sample introduction into an Ar–N2–H2 mixed-gas plasma for analysis of wheat flour by ICPMS. 1% (m/v) aerosol–OT was used as a dispersing agent to stabilize the 1% (m/m) wheat flour slurry without additional grinding. To form the mixed-gas plasma, 462 mL min−1 of N2 gas was added to the 18.5 L min−1 Ar plasma flow. The normal Ar sheath gas was replaced with 4 mL min−1 H2 gas. External calibration without internal standardization was performed using aqueous standard solutions prepared in 1% (m/v) aerosol–OT. Accurate concentrations were determined for K, Fe, Zn, Cu, Mo, and Cd despite analysis being conducted in a 0.05% Na solution. Detection limits between 0.02 and 40 mg kg−1 of bulk sample were obtained. However, severe polyatomic interferences induced by the mixed-gas plasma prevented accurate determination of Al. Nonetheless, this method should be applicable to the analysis of any dried and finely ground plant material.

Graphical abstract: Direct analysis of wheat flour by inductively coupled plasma mass spectrometry with flow injection, slurry nebulization, and a mixed-gas plasma

Article information

Article type
Technical Note
Submitted
06 Jun 2020
Accepted
02 Sep 2020
First published
02 Sep 2020

J. Anal. At. Spectrom., 2020,35, 2820-2825

Direct analysis of wheat flour by inductively coupled plasma mass spectrometry with flow injection, slurry nebulization, and a mixed-gas plasma

R. Teuma-Castelletti and D. Beauchemin, J. Anal. At. Spectrom., 2020, 35, 2820 DOI: 10.1039/D0JA00275E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements