Optimisation of laser and mass spectrometer parameters for the in situ analysis of Rb/Sr ratios by LA-ICP-MS/MS

Abstract

The Rb–Sr isotopic system is widely used in geochronology. Conventionally burdened by the isobaric overlap of 87Rb and 87Sr, Rb/Sr dating in situ has only recently become achievable with the newly developed LA-ICP-MS/MS system. Simultaneous use of reactive gas (e.g. O2, N2O, or CH3F) during LA-ICP-MS/MS analysis has been shown to resolve the Rb and Sr overlap, thus now making available key spatial and temporal information that can only be accessed via in situ analytical techniques. The accuracy and precision of Rb/Sr ratios and ages are largely dependent on the laser and ICP-MS/MS parameters used. Rb/Sr isotopic analysis by LA-ICP-MS/MS is a recently developed technique and these parameters are yet to be fully explored. We investigate the effects of laser wavelength (213 nm and 193 nm), laser frequency (5 Hz and 10 Hz), laser carrier gas (He, H2, and N2), dwell time, and external standard calibration on the accuracy and precision of 87Rb/86Sr and 87Sr/86Sr ratios and ages. These analytical conditions have been tested on the commercially available reference materials: NIST SRM 610, USGS BHVO-2G, and pressed nano-particulate powder tablet CRPG Mica-mg, as well as a Monastery phlogopite megacryst. Our results show that accuracy and precision for 87Rb/86Sr and 87Sr/86Sr ratios are significantly affected by laser wavelength and frequency. Variation in these parameters can strongly magnify any matrix effects which directly influences the ability to apply effective external corrections. We obtain the best accuracy and precision when using a 193 nm laser wavelength, ablating at a frequency of 5 Hz (0.30 2s% and 0.15 2s% for 87Rb/86Sr and 87Sr/86Sr ratios, respectively). Meanwhile we find that age accuracy is highly dependant on external reference materials. When these analytical settings are put to test on the Monastery phlogopite, we obtain an age of 90.0 ± 3.6 (0.24% accuracy) when using mica-mg (87Rb/86Sr) and NIST 610 (87Sr/86Sr) as external standards.

Graphical abstract: Optimisation of laser and mass spectrometer parameters for the in situ analysis of Rb/Sr ratios by LA-ICP-MS/MS

Supplementary files

Article information

Article type
Paper
Submitted
03 Jul 2020
Accepted
06 Aug 2020
First published
13 Aug 2020

J. Anal. At. Spectrom., 2020,35, 2322-2336

Optimisation of laser and mass spectrometer parameters for the in situ analysis of Rb/Sr ratios by LA-ICP-MS/MS

L. Gorojovsky and O. Alard, J. Anal. At. Spectrom., 2020, 35, 2322 DOI: 10.1039/D0JA00308E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements