Issue 9, 2020

PRESCIENT: platform for the rapid evaluation of antibody success using integrated microfluidics enabled technology

Abstract

Identifying antibodies (Abs) that neutralize infectious agents is the first step for developing therapeutics, vaccines, and diagnostic tools for these infectious agents. However, current approaches for identifying neutralizing Abs (nAbs) typically rely on dilution-based assays that are costly, inefficient, and only survey a small subset of the entire repertoire. There are also intrinsic biases in many steps of conventional nAb identification processes. More importantly, conventional assays rely on simple Ab–antigen binding assays, which may not result in identifying the most potent nAbs, as the strongest binder may not be the most potent nAb. Droplet microfluidic systems have the capability to overcome such limitations by conducting complex multi-step assays with high reliability, resolution, and throughput in a pico-liter volume water-in-oil emulsion droplet format. Here, we describe the development of PRESCIENT (Platform for the Rapid Evaluation of antibody SucCess using Integrated microfluidics ENabled Technology), a droplet microfluidic system that can enable high-throughput single-cell resolution identification of nAb repertoires elicited in response to viral infection. We demonstrate PRESCIENT's ability to identify Abs that neutralize a model viral agent, Murine coronavirus (murine hepatitis virus), which causes high mortality rates in experimentally infected mice. In-droplet infection of host cells by the virus was first demonstrated, followed by demonstration of in-droplet neutralization by nAbs produced from a single Ab-producing hybridoma cell. Finally, fluorescence intensity analyses of two populations of hybridoma cell lines (nAb-producing and non-nAb-producing hybridoma cell lines) successfully discriminated between the two populations. The presented strategy and platform have the potential to identify and investigate neutralizing activities against a broad range of potential infectious agents for which nAbs have yet to be discovered, significantly advancing the nAb identification process as well as reinvigorating the field of Ab discovery, characterization, and development.

Graphical abstract: PRESCIENT: platform for the rapid evaluation of antibody success using integrated microfluidics enabled technology

Supplementary files

Article information

Article type
Paper
Submitted
22 Nov 2019
Accepted
17 Feb 2020
First published
24 Feb 2020

Lab Chip, 2020,20, 1628-1638

Author version available

PRESCIENT: platform for the rapid evaluation of antibody success using integrated microfluidics enabled technology

J. A. Wippold, H. Wang, J. Tingling, J. L. Leibowitz, P. de Figueiredo and A. Han, Lab Chip, 2020, 20, 1628 DOI: 10.1039/C9LC01165J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements