Multi-corneal barrier-on-a-chip to recapitulate eye blinking shear stress forces

Abstract

Human corneal epithelium coexists with tear fluids and shows its barrier functionality under the dynamic conditions of eye blinking. However, the current in vitro cell culture settings for corneal epithelial cells lack the dynamic flow conditions to recapitulate the shear stress of eye blinking, hindering corneal function evaluation. We developed a microfluidic platform enabling the dynamic culture of the human corneal barrier with recapitulation of eye blinking. The device consisted of upper and lower channels separated by a porous membrane. Human corneal epithelial cells (HCE-T) were seeded on the porous membrane (upper channel) and cultured for ten days. The cells formed a barrier with high expression of zonula occludens 1 (ZO-1) tight junction protein on day seven, and the translocation of fluorescein sodium across the barrier in the microfluidic device was comparable to that in the transwell system, used as a control. Then, bidirectional and unidirectional flows were applied in the upper and lower channels, respectively, and the cells in the upper channels were stimulated with 0.6 dyn s cm−2 shear stress. After 24 h, while the fluid stimuli did not affect cell adhesion, they facilitated the expression of cytokeratin 19 (CK-19) intermediate filaments in cells, indicating the strengthening of the barrier function. Furthermore, morphological single-cell analysis revealed an increase in the cell body area rather than nuclei. We envision that this multi-corneal barrier-on-a-chip device will unlock new possibilities in ophthalmic drug development and will be useful for studying the effects of eye blinking shear stress on the ocular surface.

Graphical abstract: Multi-corneal barrier-on-a-chip to recapitulate eye blinking shear stress forces

Supplementary files

Article information

Article type
Paper
Submitted
23 Dec 2019
Accepted
11 Mar 2020
First published
11 Mar 2020

Lab Chip, 2020,20, 1410-1417

Multi-corneal barrier-on-a-chip to recapitulate eye blinking shear stress forces

R. Abdalkader and K. Kamei, Lab Chip, 2020, 20, 1410 DOI: 10.1039/C9LC01256G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements