Comparative study on a kilowatt-MPT-MS-based method with two ion polarity modes for the inert palladium metal

Abstract

Inert metals are of much importance and play a key role in modern industrial manufacturing. The analytical techniques of inert metals remain challenging. In particular, the mass spectrometry of inert metal elements is yet to be further developed, which also limits the contemporary conceptual in situ analysis of inert metals. As the representative element, the mass spectral detection of palladium is critical and of far-reaching significance. Herein, we developed a mass spectrometry method, which can be used for the high-speed and in situ analysis of palladium, and even for other inert metals. Combining the line ion trap mass spectrometer with the versatile ambient ionization source, a novel kilowatt microwave plasma torch (MPT) can be used to obtain the fully characteristic MPT mass spectra of palladium. Detailed multistage tandem mass spectra show that the general form of target ions is [M(O2)x(NO)mNy(NO2)n] for the negative ion mode and [M(H2O)x(NO2)y(N2)m]+ for the positive ion mode. Moreover, the formation and evolution of these palladium complex ions were reasonably derived based on the analysis of MPT background mass spectra. This mass spectrometric technique is also suitable for the determination of the palladium-containing solution in the sub-trace level. Semi-quantitative results showed that the detecting ability for palladium in the negative mode is better than that of the positive mode. Under the negative ion mode, the limit of detection (LOD) for m/z 259 were evaluated to be 0.5 μg L−1 under the optimized conditions of the negative mode, with the linear range of 1–100 μg·L−1 (R2 ≥ 0.9985) and the relative standard deviation (RSD, n = 11) being in the range of 1.20%–5.98% (refer to Table S3). Our experimental data showed that MPT-MS was a promising technique for providing another alternative in the on-site analysis of liquid samples and other intimate relevant fields, as the supplement of ICP-MS for the detection of inert metal elements. On the other hand, this work will also certainly promote the more broad applications of platinum-group elements (PGE) in modern science and industry.

Graphical abstract: Comparative study on a kilowatt-MPT-MS-based method with two ion polarity modes for the inert palladium metal

Supplementary files

Article information

Article type
Paper
Submitted
19 Oct 2020
Accepted
29 Dec 2020
First published
13 Jan 2021

Analyst, 2021,146, 1760-1771

Comparative study on a kilowatt-MPT-MS-based method with two ion polarity modes for the inert palladium metal

T. Jiang, F. Jiang, Z. Zhuo, H. Liu, B. Hu, M. Li, L. Li, Z. Huang, Z. Zhou and Z. Zhu, Analyst, 2021, 146, 1760 DOI: 10.1039/D0AN02071K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements