Issue 14, 2021

Cross-modality imaging of bisphosphonate-treated murine jawbones

Abstract

In this proof-of-principle study, we established and implemented a cross-modality imaging (CMI) pipeline to characterize and compare bisphosphonate (BIS)-treated jawbones of Sprague-Dawley rats after tooth extraction after physical therapies (photobiomodulation and extracorporeal shockwave therapy (PBMT and ESWT)). We showcase the feasibility of such a CMI approach and its compatibility across imaging modalities to probe the same region of interest (ROI) of the same jawbone. Jawbones were imaged in toto in 3D using micro-Computed Tomography to identify ROIs for subsequent sequential 2D analysis using well-established technologies such as Atomic Force Microscopy and Scanning Electron Microscopy, and recent imaging approaches in biomedical settings, such as micro-X-Ray Fluorescence Spectroscopy. By combining these four modalities, multiscale information on the morphology, topography, mechanical stiffness (Young's modulus), and calcium, zinc and phosphorus concentrations of the bone was collected. Based on the CMI pipeline, we characterized and compared the jawbones of a previously published clinically relevant rat model of BIS-related osteonecrosis of the jawbone (BRONJ) before and after treatment with BISs, PBMT and ESWT. While we did not find that physical therapies altered the mechanical and elemental jawbone parameters with significance (probably due to the small sample size of only up to 5 samples per group), both ESWT and PBMT reduced pore thicknesses and bone-to-enamel distances significantly compared to the controls. Although focused on BIS-treated jawbones, the established CMI platform can be beneficial in the study of bone-related diseases in general (such as osteoarthritis or -porosis) to acquire complementary hallmarks and better characterize disease status and alleviation potentials.

Graphical abstract: Cross-modality imaging of bisphosphonate-treated murine jawbones

Supplementary files

Article information

Article type
Paper
Submitted
10 Dec 2020
Accepted
14 May 2021
First published
01 Jul 2021
This article is Open Access
Creative Commons BY license

Analyst, 2021,146, 4683-4699

Cross-modality imaging of bisphosphonate-treated murine jawbones

S. Reier, A. Turyanskaya, P. Heimel, N. Frischauf, D. Meusburger, T. Heuser, N. Drexler, Á. Janovszky, C. Streli, P. Slezak, B. Plochberger, P. Dungel, A. Szabó and A. Walter, Analyst, 2021, 146, 4683 DOI: 10.1039/D0AN02373F

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements