Issue 6, 2021

Sonic-spray introduction of liquid samples to hand-held Ion mobility spectrometry analyzers

Abstract

Sampling hazardous compounds in the form of solids and liquids is a growing need in the fields of homeland security and forensics. Chemical analysis of particles and droplets under field conditions is crucial for various tasks carried out by counter-terrorism and law enforcement units. The use of simple, small and low cost means to achieve this goal is constantly pursued. In this work, an approach for rapid, continuous generation of vapors from liquid samples using sonic spray (SS) as the sample introduction technique, followed by analysis using hand-held ion mobility spectrometry (IMS) vapor analyzers is presented. Transfer of analytes is demonstrated from liquid state to the gas phase at the inlet of an IMS detector using a sonic spray apparatus that consists of a nebulizer, spraying solution, a source of compressed gas and an unheated transfer line tube to the detector inlet nozzle. This technique does not require any electrical, radiative or thermal energy. Analysis of several narcotic substances including cocaine, methamphetamine and amphetamine, and of an explosive compound, TNT, is demonstrated, using two commercial devices as analyzers. Two sampling configurations are presented: direct sampling of liquid, either from a vial or a spill (SS-IMS) and extraction of a substance collected with a swab by dipping it in the spray solvent (ESS-IMS), being suitable for both drops and particles. Limits of detection of the presented method are comparable to those obtained with thermal desorption sample introduction of the commercial device. Time traces of the IMS signals show a continuous and stable signal with a short rise time. This sampling technique may offer competitive performance to that of common thermal desorption techniques, with the advantages of coupling to simpler, smaller and cheaper vapor detectors, optimized for field use, and of a continuous, pulseless sample or object interrogation.

Graphical abstract: Sonic-spray introduction of liquid samples to hand-held Ion mobility spectrometry analyzers

Article information

Article type
Paper
Submitted
16 Dec 2020
Accepted
12 Jan 2021
First published
26 Jan 2021

Analyst, 2021,146, 1940-1948

Sonic-spray introduction of liquid samples to hand-held Ion mobility spectrometry analyzers

A. Pevzner, G. Feldheim, A. Zaltsman, S. Elisha, V. Heleg-Shabtai and I. Ron, Analyst, 2021, 146, 1940 DOI: 10.1039/D0AN02401E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements