Issue 21, 2021

A highly sensitive fluorescence biosensor for detection of Staphylococcus aureus based on HCR-mediated three-way DNA junction nicking enzyme assisted signal amplification

Abstract

Sensitive and efficient monitoring of food-borne bacteria is of great importance for food safety control. Herein, a novel biosensor for highly sensitive detection of Staphylococcus aureus (S. aureus) was constructed by combining hybridization chain reaction (HCR) and nicking enzyme. Different from the upstream-downstream based circuit, the proposed biosensor integrated HCR circuit and three-way DNA junction nicking enzyme assisted signal amplification (3WJ-NEASA) into a virtuous circle of promotion. In the HCR-mediated 3WJ-NEASA sensing strategy, target DNA of S. aureus initiated the self-assembly between HCR hairpins (H1 and H2), which exposed the gap to capture molecular beacon (MB) and construct the 3WJ structure. Meanwhile, MB increased the stability of HCR nanowires and enhanced the efficiency of the HCR circuit, and thus more 3WJ-NEASA circuits were generated in HCR nanowires. Benefiting from the synergistic amplification coupling HCR and 3WJ-NEASA, this isothermal biosensor can detect as low as 6.7 pM of target DNA in one step within only 30 min. Furthermore, the HCR-mediated 3WJ-NEASA assay has been applied in the detection of S. aureus with a limit of detection (LOD) as low as 1.2 × 101 cfu mL−1, and has exhibited reliable practicability in spiked milk. It is the first time that a DNA biosensor combining HCR and 3WJ-NEASA for dual signal amplification was developed and has been adopted to the sensitive analysis of food-borne bacteria. Additionally, this strategy can serve as a universal platform for monitoring other analytes, and therefore possesses broad application prospects in food safety and environmental monitoring.

Graphical abstract: A highly sensitive fluorescence biosensor for detection of Staphylococcus aureus based on HCR-mediated three-way DNA junction nicking enzyme assisted signal amplification

Supplementary files

Article information

Article type
Paper
Submitted
24 Jul 2021
Accepted
21 Aug 2021
First published
29 Aug 2021

Analyst, 2021,146, 6528-6536

A highly sensitive fluorescence biosensor for detection of Staphylococcus aureus based on HCR-mediated three-way DNA junction nicking enzyme assisted signal amplification

C. Zhang, Z. Luo, M. Wu, W. Ning, Z. Tian, Y. Duan and Y. Li, Analyst, 2021, 146, 6528 DOI: 10.1039/D1AN01335A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements