Issue 18, 2021

Inductively coupled plasma optical emission spectroscopy as a tool for evaluating lateral flow assays

Abstract

Lateral flow assays (LFAs) are immunochromatographic point-of-care devices that have greatly impacted disease diagnosis through their rapid, inexpensive, and easy-to-use form factor. While LFAs have been successful as field-deployable tools, they have a relatively poor limit of detection when compared to more complex methods. Moreover, most design and manufacturing optimization is achieved through time- and resource-intensive brute-force optimization. Despite increased interests in LFA manufacturing, more quantitative tools are needed to study current manufacturing protocols and therefore, optimize and streamline development of these devices further. In this work, we focus on a critical LFA component, colloidal gold conjugated to a detection antibody, one of the most commonly used reporter elements. This study utilizes inductively coupled plasma optical emission spectroscopy (ICP-OES) in conjunction with a lateral flow reader to quantitatively analyze colloidal gold distributions at the read-out test and control lines, as well as residual gold on the conjugate pad and other flow through regions. Our goals are to develop a more rigorous understanding of current LFA designs as well as a quantitative understanding of shortcomings of operational characteristics for future improvement. To our knowledge, this is the first time that ICP-OES has been used to study the initial distribution of colloidal gold on an unused LFA and its redistribution after a test is performed. Using three different brands of commercially available malaria LFAs, gold content was measured within each section of an LFA at varying parasite test concentrations. As expected, the total mass of gold remained unchanged after LFA use; however, the total mass of initial gold and its redistribution varied among manufacturers. Importantly, there are also some inherent inefficiencies that exist in these commercial LFA designs; for example, only 30% of the total gold deposited onto Brand A LFAs binds to the test and control lines, sections of the test that contain interpretable signal. Using information gathered with this method, future devices could be more purposefully engineered to focus on improved binding efficiency, resulting in reduced costs, improved limit of detection, and diminished test-to-test and manufacturer-to-manufacturer variability.

Graphical abstract: Inductively coupled plasma optical emission spectroscopy as a tool for evaluating lateral flow assays

Supplementary files

Article information

Article type
Paper
Submitted
09 Feb 2021
Accepted
11 Apr 2021
First published
20 Apr 2021

Anal. Methods, 2021,13, 2137-2146

Inductively coupled plasma optical emission spectroscopy as a tool for evaluating lateral flow assays

J. M. DeSousa, M. Z. Jorge, H. B. Lindsay, F. R. Haselton, D. W. Wright and T. F. Scherr, Anal. Methods, 2021, 13, 2137 DOI: 10.1039/D1AY00236H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements