High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS

Abstract

In this study, we develop a method for high precision Cd isotope analysis by double spike MC-ICP-MS. Two-step Cd purification using AG-MP-1M resin and TRU resin was used to separate Cd from samples with a recovery of more than 95% Cd and a blank less than 0.1 ng. A practical double spike design and optimization procedure is proposed and the effect of the double spike ratio in the double spike-sample mixture (p) on the measured δ114/110Cd is evaluated, which broadens the appropriate p range from 0.3–0.6 to 0.1–0.8. In addition, the observed shift/deviation of the measured δ114/110CdNIST 3108 value from zero-delta due to the change of experimental conditions is discussed on a theoretical basis and a correction approach is developed. Potential Mo and Zr based polyatomic ions have no significant effect on δ114/110Cd in typical geological samples, while isobaric ions such as Sn, Pd and In can seriously affect the accuracy of measurements even at low concentration. It is shown that the tolerances of isobaric interference can be improved to 0.1, 0.05 and 0.02 for Sn/Cd, Pd/Cd and In/Cd, respectively, after mass discrimination correction. The precision and accuracy of the proposed method were verified by analyzing mixtures of NIST 3108 and a secondary reference material BGEG-Cd of different composition. Long term monitoring of the measured NIST 3108 and BGEG-Cd showed repeatability for δ114/110Cd of 0.00 ± 0.04‰ and −1.00 ± 0.04‰ (2sd, n = 45), respectively. Finally, we measured Cd isotope compositions of several geological standard materials including soil sediments and manganese nodules, and the δ114/110Cd values of 0.01 ± 0.02‰ (GSD-5a), 0.04 ± 0.02‰ (GSD-7a), −0.06 ± 0.05‰ (GSD-10), −0.34 ± 0.06‰ (GSD-11), −0.10 ± 0.06‰ (GSD-12), 0.10 ± 0.04‰ (GSD-17), 0.05 ± 0.03‰ (GSD-21), and 0.10 ± 0.07‰ (GSD-23) were in good agreement with the reported values, and a δ114/110Cd value of −0.08 ± 0.04‰ (GSD-3a) was reported for the first time.

Graphical abstract: High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
03 Oct 2020
Accepted
30 Nov 2020
First published
08 Dec 2020

J. Anal. At. Spectrom., 2021,36, 390-398

High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS

H. Peng, D. He, R. Guo, X. Liu, N. S. Belshaw, H. Zheng, S. Hu and Z. Zhu, J. Anal. At. Spectrom., 2021, 36, 390 DOI: 10.1039/D0JA00424C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements