In situ Fe isotopic analyses of fourteen reference materials using a synthetic Cr standard for mass bias and isobaric interference corrections by femtosecond LA-MC-ICP-MS

Abstract

Highly precise and accurate measurements of Fe isotope ratios for fourteen reference materials from the USGS, MPI-DING and CGSG were successfully carried out using a developed analytical technique by fs LA-MC-ICP-MS. A synthetic standard, i.e., Cr-979S, was produced as a calibration standard for instrumental mass bias and isobaric interference corrections. The results for samples with low Cr concentration (54Cr/54Fe < 0.0001), e.g., δ56Fe values of BCR-2G (δ56Fe = 0.12 ± 0.10‰, 2SD, n = 15), were in excellent agreement with data from solution MC-ICP-MS within the measurement precision without the use of the Cr-979S standard. For the samples with high Cr concentration (54Cr/54Fe > 0.0001), e.g., BHVO-2G, δ56Fe values deviated from reference values when using the standard-sample bracketing method alone. Combining the standard-sample bracketing method with Cr-979S standard corrections and standard sample cone + H skimmer cone, the measured Fe isotopic compositions of GOR128-G and GOR132-G with extremely high Cr concentrations (54Cr/54Fe > 0.01) were identical to reference values within errors (δ56Fe = −0.01 ± 0.13‰, 2SD, n = 18; δ56Fe = 0.00 ± 0.13‰, 2SD, n = 13; respectively). A series of reference materials with varying Cr concentrations, including the USGS reference glasses (BCR-2G, BHVO-2G, BIR-1G, TB-1G, NKT-1G, GSD-1G and GSE-1G), MPI-DING reference glasses (KL2-G, ML3B-G, GOR128-G and GOR132-G) and CGSG reference materials (CGSG-1 and CGSG-4), were used to test our developed method of in situ Fe isotopic measurements using the combined standard-sample bracketing method and Cr-979S standard corrections by fs LA-MC-ICP-MS. All the reference materials yield relatively homogeneous Fe isotopic compositions with δ56Fe values ranging from −0.03‰ to 0.13‰ and δ56Fe reproducibility is below 0.15‰ (2SD), suggesting that the proposed isobaric interference correction and mass bias correction method is a useful tool for providing high-quality in situ Fe isotopic data of geological samples with both low and high Cr concentrations.

Graphical abstract: In situ Fe isotopic analyses of fourteen reference materials using a synthetic Cr standard for mass bias and isobaric interference corrections by femtosecond LA-MC-ICP-MS

Supplementary files

Article information

Article type
Technical Note
Submitted
08 Nov 2020
Accepted
22 Feb 2021
First published
22 Feb 2021

J. Anal. At. Spectrom., 2021,36, 747-757

In situ Fe isotopic analyses of fourteen reference materials using a synthetic Cr standard for mass bias and isobaric interference corrections by femtosecond LA-MC-ICP-MS

L. Xu, W. Zhang, T. Luo, J. Yang and Z. Hu, J. Anal. At. Spectrom., 2021, 36, 747 DOI: 10.1039/D0JA00465K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements