Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample specimen

Abstract

An excellent improvement in the detection limit is achieved using a lab-based micro-X-ray fluorescence (micro-XRF) spectrometer equipped with a low-power X-ray tube that utilizes the entire bremsstrahlung spectrum emitted from the tube, for excitation. The beam was further passed through polycapillary optics in order to focus it over a spot of 35 μm × 50 μm. The minimum detection limit (MDL) achieved using the present methodology is down to 0.4–4 ng mL−1 for elements ranging from medium to high Z. For some elements, the as-obtained MDL is almost 6–60 times lower than that obtained using the lab-based total reflection X-ray fluorescence (TXRF) spectrometer using the same excitation source. This is the lowest detection limit achieved to date using lab-based XRF instrument in energy dispersive X-ray fluorescence (EDXRF) geometry to the best of our knowledge. Further, the instrumentation is very simple, straightforward and does not involve any complicated alignment procedure as in the TXRF geometry. The developed methodology requires deposition and drying of only 5 μL of the liquid sample specimen on a thin transparent scotch tape to form a thin film sample specimen and it can be directly used for measurements. Using this methodology, we could determine trace elemental concentration in water samples at an ultra-trace level (few ng mL−1) without any complicated pre-concentration or alignment procedure. As the developed methodology is very simple and less time-consuming, it is comparable with the TXRF technique for the routine analysis of different water samples with elements present at ultra-trace levels.

Graphical abstract: Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample specimen

Supplementary files

Article information

Article type
Paper
Submitted
04 Dec 2020
Accepted
04 Mar 2021
First published
04 Mar 2021

J. Anal. At. Spectrom., 2021,36, 803-812

Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample specimen

K. Sanyal, B. Kanrar and S. Dhara, J. Anal. At. Spectrom., 2021, 36, 803 DOI: 10.1039/D0JA00499E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements