High-precision analysis of potassium isotopes by MC-ICP-MS without collision cell using cool plasma technique in low-resolution mode

Abstract

This study presents a method for high-precision stable potassium (K) isotope analysis using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) without a collision cell in low-resolution mode. The cold plasma technique (RF power of ∼600 W) combined with wet plasma was used to suppress the formation of argon hydrides, which are direct isobaric interference to K ions. The remaining ArH+ interference was deducted by measurements from the blank acid before and after each measurement. Using this analytical method, precision of better than 0.08‰ (2SD) for 41K/39K could be achieved based on routine measurements of pure K solution during a six-month period. The effects of matrix elements, acid strength, ArH+ percentage and concentration mismatch on the precision of the K isotope measurement were also evaluated. Mismatches in K concentration (up to 20%) between samples and bracketing standards did not affect the precision and accuracy significantly, whereas the precision and accuracy were very sensitive to mismatches in acid molarity. Thus, the same batch of acid is needed to dissolve samples and bracketing standards. The measured potassium isotopic compositions of international rock standards using the present method agreed well, within analytical precisions, with previously reported values. We believe that this contribution will accelerate the output efficiency of K isotope data and motivate the use of potassium isotopes as potential tracers in geosciences.

Graphical abstract: High-precision analysis of potassium isotopes by MC-ICP-MS without collision cell using cool plasma technique in low-resolution mode

Supplementary files

Article information

Article type
Paper
Submitted
10 Jun 2021
Accepted
01 Oct 2021
First published
01 Oct 2021

J. Anal. At. Spectrom., 2021,36, 2545-2552

High-precision analysis of potassium isotopes by MC-ICP-MS without collision cell using cool plasma technique in low-resolution mode

H. Gu and H. Sun, J. Anal. At. Spectrom., 2021, 36, 2545 DOI: 10.1039/D1JA00201E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements