Issue 11, 2022

Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS

Abstract

The precise determination of Cd isotope ratios via multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has made the widespread application of Cd isotopes possible. However, previous studies are complicated by the chemical purification method and molecular interferences from Zn (e.g.70Zn36Ar+, 68Zn38Ar+, and 66Zn40Ar+ on 106Cd+, 70Zn38Ar+ and 68Zn40Ar+ on 108Cd+, 70Zn40Ar+ on 110Cd+). Separation of Zn from Cd requires the usage of a toxic reagent (HBr) and is also complicated by the relatively high procedural Zn blank especially when only a very small amount of Cd is available. Here we present a high-precision Cd isotope measurement method using double spike MC-ICP-MS, which avoids the molecular interferences from Zn introduced by both sample and chemical purification. A 111Cd–113Cd double spike pair optimized for the 111Cd, 112Cd, 113Cd, and 114Cd inversion was used to correct for the mass bias. Elemental doping experiments suggest that the measured Cd isotope data were not significantly affected when the measured solution has, Zn/Cd < 103, Pd/Cd < 102, Fe/Cd < 10−2, In/Cd < 10−3, Sn/Cd < 10−1, Zr/Cd < 10−2, Nb/Cd < 10−1, Mo/Cd < 10−2, Ru/Cd < 10−2, Ga/Cd < 10−2, Ge/Cd < 10−2, Se/Cd < 10−1, and As/Cd < 10−1. We thus modified the chemical purification method by removing the HBr step and eluting Zn and Cd together. The minimum requirement of sample size for precise measurement of stable Cd isotope ratios was tested to be as low as 10 ng. The measurements of pure Cd solutions (BAM I012 Cd and HPS Cd) give a long-term intermediate precision for δ114/110Cd relative to NIST SRM 3108 of 0.05‰. We further validated our method by measuring different reference materials covering a relatively wide range of Zn/Cd (∼9 to 1239), the results of which agree within uncertainty with previous studies. Our study thus provides an efficient and precise way to determine stable Cd isotope ratios of geological samples with relatively low Cd concentrations.

Graphical abstract: Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
19 Jul 2022
Accepted
13 Oct 2022
First published
14 Oct 2022

J. Anal. At. Spectrom., 2022,37, 2470-2479

Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS

C. Guo, T. Li, G. Li, T. Chen, L. Li, L. Zhao and J. Ji, J. Anal. At. Spectrom., 2022, 37, 2470 DOI: 10.1039/D2JA00250G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.